Well-type HPGe-detector absolute-peak-efficiency calibration and true-coincidence correction

被引:0
|
作者
Wang, Tien-Ko [1 ]
Hou, I.-Min [1 ]
Tseng, Chia-Lian [1 ]
机构
[1] Dept. of Eng. and System Science, National Tsing Hua University, Hsinchu 30043, Taiwan
关键词
Number:; -; Acronym:; NSC; Sponsor: National Science Council;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:504 / 515
相关论文
共 28 条
  • [21] A simple method for self-attenuation correction in 210Pb activity measurement in a well-type HPGe detector
    Rodriguez Vegas, Eva
    Antonio Suarez-Navarro, Jose
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 312 (02) : 199 - 204
  • [22] Experimental verification of mathematical efficiency modeling and true coincidence summing correction of the SAGe Well detector
    Jaederstroem, Henrik
    Adekola, Aderemi S.
    Atrashkevich, Valery
    Mueller, Wilhelm F.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 1961 - 1966
  • [23] Experimental verification of mathematical efficiency modeling and true coincidence summing correction of the SAGe Well detector
    Henrik Jäderström
    Aderemi S. Adekola
    Valery Atrashkevich
    Wilhelm F. Mueller
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 1961 - 1966
  • [24] A simple method for self-attenuation correction in 210Pb activity measurement in a well-type HPGe detector
    Eva Rodríguez Vegas
    Jose Antonio Suarez-Navarro
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 312 : 199 - 204
  • [25] The determination of 125I activity using sum-peak method with a well-type HPGe-detector-based spectrometer
    Wang, ZL
    Zhang, XL
    Chang, YF
    Liu, DM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 459 (03): : 475 - 481
  • [26] Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors
    Laborie, JM
    Le Petit, G
    Abt, D
    Girard, M
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 57 - 62
  • [27] A numerical approach to calculate the full-energy peak efficiency of HPGe well-type detectors using the effective solid angle ratio
    Badawi, M. S.
    Ruskov, I.
    Gouda, M. M.
    El-Khatib, A. M.
    Alotiby, M. F.
    Mohamed, M. M.
    Thabet, A. A.
    Abbas, M. I.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [28] CALIBRATION OF A WELL-TYPE NAI(TI)-DETECTOR FOR ABSOLUTE COUNTING OF GASEOUS KR-85 AND XE-133
    CEJNAR, F
    KOVAR, I
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1977, 30 (5-6): : 341 - 348