Fluorimetric Determination of Bromate by Ion-Exchange Separation and Post-Column Derivatization

被引:3
|
作者
Institute of Hydrochemistry, Technical University of Munich, Marchioninistr. 17, D-81377 Munich, Germany [1 ]
机构
来源
Mikrochimica Acta | 1998年 / 129卷 / 03期
关键词
Azo dyes - Fluorescence - Ion exchange - Ions - Nitrogen compounds - Sulfur compounds - Water injection;
D O I
暂无
中图分类号
学科分类号
摘要
For the determination of bromate in drinking water a stopped-flow post-column reaction was developed following the separation of bromate from the matrix by an anion-exchange column. In the post-column reaction the analyte was used to oxidize the azo dye sulfonaphtholazoresorcinol, SNAR, and the residual amount was converted into a fluorescent binuclear complex by an excess of gallium ions. The fluorescence was monitored at 585 nm, with a maximum excitation wavelength at 521 nm. The determination of bromate is based on the decrease of the fluorescence intensity with increasing bromate concentration. The given hydrodynamic parameters and the condition of equal flow rates of the two branch streams at each T-piece have to be considered as an important criterion for the experimental set-up. The volume flows and the concentrations required for the reagent solutions in the influent of each T-piece were determined as a result of batch experiments and theoretical considerations. The limit of detection was 0.28 μgL-1bromate for the flow method, which shows linearity up to 15 μgL-1 bromate.
引用
收藏
页码:281 / 290
相关论文
共 50 条
  • [31] ION-EXCHANGE BEHAVIOR OF COPPER FERRICYANIDE - APPLICATION OF ION-EXCHANGE COLUMN TO THE SEPARATION OF CS
    JAIN, AK
    SINGH, RP
    BALA, C
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1982, 75 (1-2): : 85 - 95
  • [33] CATECHOLAMINES - ONLINE QUANTIFICATION AND POST-COLUMN DERIVATIZATION
    BOOS, KS
    WILMERS, B
    SAUERBREY, R
    SCHLIMME, E
    CHROMATOGRAPHIA, 1988, 25 (03) : 199 - 204
  • [34] LIQUID-CHROMATOGRAPHY WITH POST-COLUMN DERIVATIZATION
    FREI, RW
    BRINKMAN, UAT
    ACTA PHARMACEUTICA SUECICA, 1982, 19 (01): : 65 - 65
  • [35] Enhancing the determination of sulfonic acids using anion-exchange chromatography with post-column derivatization and spectrometric detection
    Huang, Jinmo
    Weisensee, Corrie
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (04) : 509 - 516
  • [36] Determination of bromate in water samples using post column derivatization method with triiodide
    Michalski, Rajmund
    Lyko, Aleksandra
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2010, 45 (10): : 1275 - 1280
  • [37] Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography
    Wu, Shuchao
    Xu, Wei
    Yang, Bingcheng
    Ye, Mingli
    Zhang, Peimin
    Chao Shen-Tu
    Zhu, Yan
    ANALYTICA CHIMICA ACTA, 2012, 735 : 62 - 68
  • [38] HPLC determination of tetracycline antibiotics in milk with post-column derivatization and fluorescence detection
    Kargin, I. D.
    Sokolova, L. S.
    Pirogov, A. V.
    Shpigun, O. A.
    INORGANIC MATERIALS, 2016, 52 (14) : 1365 - 1369
  • [39] HPLC determination of tetracycline antibiotics in milk with post-column derivatization and fluorescence detection
    I. D. Kargin
    L. S. Sokolova
    A. V. Pirogov
    O. A. Shpigun
    Inorganic Materials, 2016, 52 : 1365 - 1369
  • [40] Determination of butocarboxim residue in agricultural products by HPLC with post-column derivatization system
    Tseng, SH
    Chang, PC
    Chou, SS
    JOURNAL OF FOOD AND DRUG ANALYSIS, 1999, 7 (04) : 269 - 277