Individualized Air Conditioning - System in Comparison.

被引:0
|
作者
Bockwyt, Heinz
机构
来源
Klima, Kalte, Heizung | 1988年 / 16卷 / 05期
关键词
BLOWERS - ENERGY CONSERVATION;
D O I
暂无
中图分类号
学科分类号
摘要
The article compares decentralized air conditioning systems for individual rooms. Particular interest is taken in decentralized individual air conditioning units with blower convectors. These systems have a marked advantage especially if rooms are used for different purposes. Energy is supplied at low cost by circulating water. If rooms or parts of a building are not used at a given moment, the systems can be shut off in order to minimize costs. Ambient air can be pretreated and supplied to the blower convector via a primary air processing unit; alternatively, primary air can be taken in by the blower convector directly through the outer wall. The second alternative provides partial air conditioning at very low cost.
引用
收藏
页码:215 / 221
相关论文
共 50 条
  • [41] Comparison between the chiller air cooled with the variable refrigerant flow technology for high building air conditioning system
    Arifin, Z.
    Wahyu, W.
    5TH ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2020), 2021, 1098
  • [42] TRAINING - A FRAMEWORK FOR COMPARISON.
    Cave, B.J.
    Foundryman, 1982, 75 (pt 12): : 225 - 232
  • [43] Thermoeconomic diagnosis of an air-cooled air conditioning system
    Yoo, Yungpil
    Oh, Hoo-Suk
    Uysal, Cuneyt
    Kwak, Ho-Young
    INTERNATIONAL JOURNAL OF EXERGY, 2018, 26 (04) : 393 - 417
  • [44] AIR-CONDITIONING SYSTEM USING A COLD AIR REFRIGERATOR
    LUBENETS, VV
    RUSSIAN ENGINEERING JOURNAL, 1978, 58 (07): : 22 - 25
  • [45] Design and comparison of model-based controllers for an automotive air conditioning system in an electric vehicle
    Goeltz, Stefanie
    Sawodny, Oliver
    CONTROL ENGINEERING PRACTICE, 2023, 130
  • [46] Comparison of Modelled and Measured Heat and Mass Transfer in a Liquid Desiccant Air-Conditioning System
    Mandow, Wael
    Muetzel, Martin
    Fleig, Daniel
    Lowenstein, Andrew
    Jordan, Ulrike
    PROCEEDINGS OF THE ISES EUROSUN 2018 CONFERENCE - 12TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2018, : 648 - 658
  • [47] Performance comparison between two novel configurations of liquid desiccant air-conditioning system
    Tu, Min
    Ren, Cheng-Qin
    Tang, Guang-Fa
    Zhao, Zhen-Sheng
    BUILDING AND ENVIRONMENT, 2010, 45 (12) : 2808 - 2816
  • [48] Performance optimization and comparison of two hybrid regeneration methods for absorption air-conditioning system
    Zhang, Wanshi
    Ding, Boqing
    Wu, Yunlei
    Li, Xiuwei
    Cheng, Feng
    Zhang, Xiaosong
    SOLAR ENERGY, 2023, 249 : 81 - 97
  • [49] Comparison of Conventional and Variable Borehole Heat Exchangers for Use in a Desiccant Assisted Air Conditioning System
    Richter, Finn
    Niemann, Peter
    Schuck, Matthias
    Grabe, Jurgen
    Schmitz, Gerhard
    ENERGIES, 2021, 14 (04)
  • [50] Experimental determination of instantaneous cooling capacity of the bus air conditioning system, and comparison of analytical results
    Unal, Saban
    Energy Education Science and Technology Part A: Energy Science and Research, 2012, 30 (SPEC .ISS.1): : 711 - 718