Suppression of in-cell generated interferences in a reaction cell ICP-MS by bandpass tuning and kinetic energy discrimination

被引:0
|
作者
机构
[1] Hattendorf, Bodo
[2] Günther, Detlef
来源
Hattendorf, B. (bodo@inorg.chem.ethz.ch) | 1600年 / Royal Society of Chemistry卷 / 19期
关键词
Gas dynamics - Impurities - Inductively coupled plasma - Kinetic energy - Mass spectrometers - Oxygen - Positive ions - Reaction kinetics;
D O I
暂无
中图分类号
学科分类号
摘要
The efficiency of kinetic energy discrimination and bandpass tuning for the suppression of potentially interfering product ions, formed by ion-molecule reactions in a dynamic reaction cell of an inductively coupled plasma mass spectrometer is compared. Suppression of the oxide ions from Sc+, Y+, La+ and Th+, formed in reactions with oxygen impurities in non-reactive gases, have been used as test system to determine the suppression efficiency of the in-cell generated ions in dependence of the operating parameters of a dynamic reaction cell. Kinetic energy discrimination was investigated by successively lowering the pole bias voltage of the reaction cell quadrupole below the pole bias of the analyser quadrupole to create a potential barrier of increasing height. For bandpass tuning, the transmission window of the reaction cell quadrupole was successively narrowed to determine the cut-off mlz, where precursors of the product ions are rejected. The efficiency of interference suppression and the elemental sensitivity are in all cases decreasing with mlz of the precursor ions. Both approaches allow the suppression of the in-cell generated ScO+ and YO+, while LaO+ and to a greater extent ThO+ cannot be fully eliminated without compromising elemental sensitivity significantly. LaO + and ThO+ are observed at levels, which are by a factor of two and six higher than in standard operation of the ICP-MS. Elemental sensitivity is higher by approximately a factor of five and the abundance of the cell produced ions is reduced more effectively with the bandpass tuning approach when compared to kinetic energy discrimination.
引用
收藏
相关论文
共 50 条
  • [21] The effect of ion energy on reactivity and species selectivity in hexapole collision/reaction cell ICP-MS
    Dexter, MA
    Reid, HJ
    Sharp, BL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) : 676 - 681
  • [22] Determination of selenium in milk powder by octopole reaction cell ICP-MS
    Cho, Sung-Eel
    Kim, Mi-Ju
    Kim, Yong-Ha
    Min, Young-Keun
    Kim, Young-Sang
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (03): : 203 - 210
  • [23] Vanadium determination in chloride matrices using ICP-MS:: finding the optimum collision/reaction cell parameters for suppressing polyatomic interferences
    Chrastny, Vladislav
    Komarek, Michael
    Mihaljevic, Martin
    Stichova, Jana
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (05) : 962 - 970
  • [24] Vanadium determination in chloride matrices using ICP-MS: finding the optimum collision/reaction cell parameters for suppressing polyatomic interferences
    Vladislav Chrastný
    Michael Komárek
    Martin Mihaljevič
    Jana Štíchová
    Analytical and Bioanalytical Chemistry, 2006, 385 : 962 - 970
  • [25] Multielemental determination in oil matrices diluted in xylene by ICP-MS with a dynamic reaction cell employing methane as reaction gas for solving specific interferences
    de Souza, Jefferson R.
    Duyck, Christiane B.
    Fonseca, Teresa C. O.
    Saint'Pierre, Tatiana D.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (08) : 1280 - 1286
  • [26] Collision/Reaction Cell ICP-MS with Shielded Torch and Sector Field ICP-MS for the Simultaneous Determination of Selenium Isotopes in Biological Matrices
    Al-Saad, Khalid A.
    Amr, Mohammed A.
    Helal, Abdulfattah I.
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2011, 140 (01) : 103 - 113
  • [27] Collision/Reaction Cell ICP-MS with Shielded Torch and Sector Field ICP-MS for the Simultaneous Determination of Selenium Isotopes in Biological Matrices
    Khalid A. Al-Saad
    Mohammed A. Amr
    Abdulfattah I. Helal
    Biological Trace Element Research, 2011, 140 : 103 - 113
  • [28] Multielement analysis of human seminal plasma by octopole reaction cell ICP-MS
    20144300126370
    Živković, Tanja, 1600, Royal Society of Chemistry (29):
  • [29] Multielement analysis of human seminal plasma by octopole reaction cell ICP-MS
    Zivkovic, Tanja
    Tariba, Blanka
    Pizent, Alica
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (11) : 2114 - 2126
  • [30] A reaction cell as a sample introduction portal for detection of gaseous components in ICP-MS
    Hirata, Takafumi
    Kobayashi, Kyoko
    Asanuma, Hisashi
    Makino, Yoshiki
    Yamashita, Shuji
    Kurihara, Kanoko
    Niki, Sota
    Nakazato, Masaki
    Shikino, Osamu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (02) : 518 - 524