SPACER EFFECT ON THE SYNTHESIS OF OLIGODEOXYNUCLEOTIDES BY THE PHOSPHITE METHOD.

被引:0
|
作者
Katzhendler, J. [1 ]
Cohen, S. [1 ]
Weisz, M. [1 ]
Ringel, I. [1 ]
Camerini-Oterio, R.D. [1 ]
Deutsch, J. [1 ]
机构
[1] Hebrew Univ of Jerusalem, Jerusalem, Isr, Hebrew Univ of Jerusalem, Jerusalem, Isr
来源
关键词
Biological materials - OLIGOMERS - Synthesis - SILICA GEL - Applications;
D O I
暂无
中图分类号
学科分类号
摘要
Nineteen oligonucleotides of 15-27 bases long were synthesized on aminoalkyl spacers of various chain lengths, Si-O-(CH//2)//3NHCONH(CH//2)//nNHCO(CH//2)//mNH//2, linked to Fractosil silica gel supports (F6, F12, F15, F18, F21, F24, F32, F38), to Porasil (P15) silica gel support, and to modified controlled pore glass (CPG17, CPG24). The purity and the homogenity of the end product in the reaction mixture was quantitatively determined from the autoradiograph pattern of bands on polyacrylamide sizing gel. The data indicated that the most pure products are obtained either on the shortest spacer, F6, or on the 24, 32, or 38 atom length spacers. Spacer lengths of 15, 18 and 21 atoms gave very poor results, with large amounts of impurities. The results are interpreted on the basis of conformational changes in the spacer alkyl chain as a function of its length.
引用
收藏
页码:175 / 187
相关论文
共 50 条
  • [41] AN IMPROVED METHOD FOR THE PREPARATION OF METHYL DICHLOROPHOSPHITE - A KEY REAGENT IN THE PHOSPHITE METHOD OF OLIGONUCLEOTIDE SYNTHESIS
    TASHMA, Z
    RINGEL, I
    DEUTSCH, J
    COHEN, S
    WEISZ, M
    KATZHENDLER, J
    NUCLEOSIDES & NUCLEOTIDES, 1987, 6 (03): : 589 - 595
  • [42] Determination of enzymatic effect of nuclease using the optical method.
    Pighini, G
    HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1910, 70 (2/3): : 85 - 93
  • [43] Effect of acids on dentin permeability using an impedance method.
    Pradelle, N
    Wenger, F
    Colon, P
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B285 - B285
  • [44] THE EFFECT OF SPACER, LINKAGE AND SOLID SUPPORT ON THE SYNTHESIS OF OLIGONUCLEOTIDES
    KATZHENDLER, J
    COHEN, S
    RAHAMIM, E
    WEISZ, M
    RINGEL, I
    DEUTSCH, J
    TETRAHEDRON, 1989, 45 (09) : 2777 - 2792
  • [45] Synthesis of autofocusing system for magnetooptical storage by the motion division method. Method correctness
    Voevoda, A.A.
    Zhmud', V.A.
    Avtometriya, 1992, (02): : 59 - 66
  • [46] EFFECT OF TESTING TECHNOLOGY ON THE RECOGNITION OF DEFECTS BY THE CAPILLARY METHOD.
    Khan'zhin, P.S.
    Yablonik, L.M.
    The Soviet journal of nondestructive testing, 1980, 16 (06): : 465 - 470
  • [47] A discourse on the method.
    Ariew, Roger
    MODERN LANGUAGE REVIEW, 2007, 102 : 231 - 231
  • [48] The Decroly method.
    不详
    ANNEE PSYCHOLOGIQUE, 1922, 23 : 549 - 551
  • [49] The fluoroscopic method.
    Brown, P
    BOSTON MEDICAL AND SURGICAL JOURNAL, 1913, 168 : 0219 - 0220
  • [50] On the histotopographical method.
    Ciechanowski, S
    VIRCHOWS ARCHIV FUR PATHOLOGISCHE ANATOMIE UND PHYSIOLOGIE UND FUR KLINISCHE MEDIZIN, 1925, 256 (02): : 568 - 568