INHIBITOR FILM PERSISTENCE MEASUREMENT BY ELECTROCHEMICAL TECHNIQUES.

被引:0
|
作者
Choi, H.J. [1 ]
Cepulis, R.L. [1 ]
机构
[1] Standard Oil Production Co, USA, Standard Oil Production Co, USA
来源
SPE Production Engineering | 1987年 / 2卷 / 04期
关键词
CORROSION PROTECTION - Inhibitors - STEEL CORROSION - Pitting;
D O I
10.2118/13555-PA
中图分类号
学科分类号
摘要
A technique that uses corrosion-potential, PHI //c//o//r//r, measurements was developed to evaluate rapidly the film persistence of commercial adsorption-type inhibitors for downhole tubular treatment. It was demonstrated that the PHI //c//o//r//r measurement revealed the progressive change with time of inhibitor film in aqueous moving fluids. The advantages of PHI //c//o//r//r measurements are that film effectiveness can be monitored continuously with a simple device and that they are nonintrusive. Additional results of the tests showed that dissolved O//2, CO//2, and fluid flow drastically degraded the effectiveness of inhibitor film, and higher concentrations of inhibitors provided better performance. These indicate that simulation of process conditions is a prerequisite when the film persistence of commercial adsorption-type inhibitors is determined in a laboratory.
引用
收藏
页码:325 / 330