Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures

被引:0
|
作者
Division of Radiological Sciences, U. Med. Dent. Schools Guy's St. T., Guy's Hospital, London Bridge, London, SE1 9RT, United Kingdom [1 ]
机构
来源
MED. PHYS. | / 1卷 / 25-35期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery
    Laurence Mercier
    Vladimir Fonov
    Claire Haegelen
    Rolando F. Del Maestro
    Kevin Petrecca
    D. Louis Collins
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 125 - 136
  • [22] Accurate three-dimensional registration of magnetic resonance images for detecting local changes in cartilage thickness
    Cheng, Yuanzhi
    Jin, Quan
    Zhao, Jie
    Guo, Changyong
    Bai, Jing
    JOURNAL OF ELECTRONIC IMAGING, 2011, 20 (02)
  • [23] Automatic three-dimensional registration of intravascular optical coherence tomography images
    Ughi, Giovanni J.
    Adriaenssens, Tom
    Larsson, Matilda
    Dubois, Christophe
    Sinnaeve, Peter R.
    Coosemans, Mark
    Desmet, Walter
    D'hooge, Jan
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (02)
  • [24] Fourier approaches for fully three-dimensional reconstruction in positron emission tomography
    Matej, S
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, PROCEEDINGS, 2002, : 245 - 251
  • [25] Multiresolution discrete optimization registration method of ultrasound and magnetic resonance images based on key points
    Tan Z.
    Guo S.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (02): : 202 - 207
  • [26] 2-DIMENSIONAL REGISTRATION OF MAGNETIC-RESONANCE BRAIN IMAGES
    FITCHARD, EF
    NARAYANA, PA
    MEDICAL PHYSICS, 1994, 21 (08) : 1333 - 1337
  • [27] Optimization of noninvasive activation studies with O-15-water and three-dimensional positron emission tomography
    Sadato, N
    Carson, RE
    DaubeWitherspoon, ME
    Campbell, G
    Hallett, M
    Herscovitch, P
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (07): : 732 - 739
  • [28] Normal fusion for three-dimensional integrated visualization of SPECT and magnetic resonance brain images
    Stokking, R
    Zuiderveld, KJ
    Pol, HEH
    vanRijk, PP
    Viergever, MA
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (04) : 624 - 629
  • [29] Coregistration of brain single-positron emission computed tomography and magnetic resonance images using anatomical features
    Lucas Ferrari de Oliveira
    P. M. Azevedo Marques
    Journal of Digital Imaging, 2000, 13 : 196 - 199
  • [30] Coregistration of brain single-positron emission computed tomography and magnetic resonance images using anatomical features
    De Oliveira, Lucas Ferrari
    Marques, P.M. Azevedo
    Journal of Digital Imaging, 2000, 13 (2 SUPPL. 1) : 196 - 199