Regeneration of an electropolymerised polypyrrole layer for the amperometric detection of ammonia

被引:0
|
作者
Univ. of Münster Eye Hospital, Experimental Ophthalmology, Domagkstraße 15, D-48149 Münster, Germany [1 ]
不详 [2 ]
机构
来源
Biosens. Bioelectron. | / 12卷 / 1227-1231期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
19
引用
收藏
相关论文
共 50 条
  • [1] Regeneration of an electropolymerised polypyrrole layer for the amperometric detection of ammonia
    Heiduschka, P
    Preschel, M
    Rosch, M
    Gopel, W
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (12): : 1227 - 1231
  • [2] A polypyrrole-based amperometric ammonia sensor
    Lahdesmaki, I
    Lewenstam, A
    Ivaska, A
    TALANTA, 1996, 43 (01) : 125 - 134
  • [3] Interferences in a polypyrrole-based amperometric ammonia sensor
    Lähdesmäki, I
    Kubiak, WW
    Lewenstam, A
    Ivaska, A
    TALANTA, 2000, 52 (02) : 269 - 275
  • [4] On line mass spectrometric detection of ammonia oxidation products generated by polypyrrole based amperometric sensors
    Vidotti, M
    Dall'Antonia, LH
    de Torresi, SIC
    Bergamaski, K
    Nart, FC
    ANALYTICA CHIMICA ACTA, 2003, 489 (02) : 207 - 214
  • [5] Influence of the preparation conditions on the properties of electropolymerised polypyrrole
    Brandl, V
    Holze, R
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1998, 102 (08): : 1032 - 1038
  • [6] Properties of electropolymerised polypyrrole thin film on silver
    Jamadade, Shivaji A.
    Puri, Vijaya
    APPLIED SURFACE SCIENCE, 2009, 255 (19) : 8281 - 8285
  • [7] POLYPYRROLE FILMS ELECTROPOLYMERISED IN SODIUM DODECYLSULPHATE SOLUTION
    Zerbino, Jorge O.
    Falivene, Claudio
    Maltz, Alberto
    Sustersic, Maria G.
    AVANCES EN CIENCIAS E INGENIERIA, 2010, 1 (04): : 23 - 32
  • [8] Flow Injection Amperometric Detection of Ammonia Using a Polypyrrole-Modified Electrode and Its Application in Urea and Creatinine Biosensors
    Trojanowicz, M.
    Lewenstam, A.
    Krawczynski Vel Krawczyk, T.
    Laehdesmaeki, I.
    Electroanalysis, 8 (03):
  • [9] Flow injection amperometric detection of ammonia using a polypyrrole-modified electrode and its application in urea and creatinine biosensors
    Trojanowicz, M
    Lewenstam, A
    Krawczyk, TKV
    Lahdesmaki, I
    Szczepek, W
    ELECTROANALYSIS, 1996, 8 (03) : 233 - 243
  • [10] Flow Injection Amperometric Detection of Ammonia Using a Polypyrrole-Modified Electrode and Its Application in Urea and Creatinine Biosensors
    Trojanowicz, Marek
    Lewenstam, Andrzej
    Krawczyński Vel Krawczyk, Tadeusz
    Lähdesmäki, Ilkka
    Szczepek, Wojciech
    1996, Wiley-VCH Verlag (08)