AUTOMATIC DEVICE FOR MAINTAINING A CONSTANT LIQUID-NITROGEN LEVEL.

被引:0
|
作者
Batrakov, B.P.
Kravchenko, V.A.
Ermakov, E.B.
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A description is given of an automatic electronic device for maintaining a constant level of liquid nitrogen, in which a plane air capacitor immersed in liquid nitrogen is used as the liquid-level sensor (the permittivity of the liquid and of the gaseous nitrogen differ by a factor of 1. 4). For a change in the level of liquid nitrogen the sensor capacitance changes, and there is a corresponding change in oscillator frequency. As a result, cutoff of the oscillations of the Q-multiplier occurs. The voltage which blocks the dc amplifier vanishes, and it unblocks and turns on the relay. The control voltage is applied to the thyristor through the relay contacts, and the thyristor turns on the electromagnetic valve that controls the feed of liquid nitrogen As soon as the liquid nitrogen reaches the stipulated level, the circuit returns to its original state. The accuracy with which the level of the liquid nitrogen is maintained constant equals 1. 5 to 2 mm. A schematic diagram is given.
引用
收藏
页码:1631 / 1632
相关论文
共 50 条
  • [41] DEVICE FOR CONTROL OF LIQUID-NITROGEN LEVELS (EXCHANGE OF EXPERIENCE)
    ZARUKIN, AI
    VALEEV, EY
    SHIROKOV, AA
    MALTSEVA, LF
    INDUSTRIAL LABORATORY, 1976, 42 (09): : 1443 - 1444
  • [42] LIQUID-NITROGEN
    LINDSAY, WN
    CHEMICAL & ENGINEERING NEWS, 1987, 65 (24) : 2 - 2
  • [43] SIGNALIZATION EQUIPMENT FOR CONTROLLING LIQUID-NITROGEN LEVEL IN A RESERVOIR
    HANZLIK, J
    KNOR, Z
    CHEMICKE LISTY, 1987, 81 (01): : 98 - 108
  • [44] A MINIATURE CENTRIFUGAL PUMP FOR AN AUTOMATIC LIQUID-NITROGEN FILLING SYSTEM
    HARUYAMA, T
    YOSHIZAKI, R
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1986, 19 (11): : 919 - 921
  • [45] An automatic liquid-nitrogen filling system for multiple Ge detectors
    Koizumi, Mitsuo
    Oshima, Masumi
    Toh, Yosuke
    Kimura, Atsushi
    Kin, Tadahiro
    Furutaka, Kazuyoshi
    Murakami, Yukihiro
    Osa, Akihiko
    Ando, Shingo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (01):
  • [46] DEVICE FOR POWER FEED OF LIQUID-NITROGEN IN CRYOSTAT FOR SPECTROPHOTOMETRIC MEASUREMENTS
    POLEVOI, PS
    ENDZHEICHAK, B
    ZHURNAL FIZICHESKOI KHIMII, 1977, 51 (06): : 1554 - 1555
  • [47] A SIMPLE LIQUID NITROGEN CONSTANT LEVEL
    CRISP, RS
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1970, 3 (07): : 566 - &
  • [48] PRICING LIQUID-NITROGEN
    ARONSON, D
    SCIENCE 85, 1985, 6 (05): : 16 - 16
  • [49] LIQUID-NITROGEN IN DERMATOLOGY
    AUBINIERE, E
    REVUE DU PRATICIEN, 1984, 34 (56): : 3166 - 3167
  • [50] RATIONALIZATION WITH LIQUID-NITROGEN
    REBHAN, D
    GUMMI ASBEST KUNSTSTOFFE, 1981, 34 (06): : 374 - &