Cleaning of electron beam-induced contamination in the electron beam column

被引:0
|
作者
Yamazaki, Y. [1 ]
Ohotoshi, K. [1 ]
Sakai, I. [1 ]
Sugihara, K. [1 ]
Miyoshi, M. [1 ]
机构
[1] Toshiba Corp, Kawasaki, Japan
来源
Optik (Jena) | 1994年 / 97卷 / 02期
关键词
Carbon - Cleaning - Contamination - Etching - Flow of fluids - Mixtures - Optical films - Oxides - Photoresists - Pressure - Removal;
D O I
暂无
中图分类号
学科分类号
摘要
The parameters for cleaning of electron beam-induced carbon contamination were investigated. Reactive species of O2 and CF4 gas mixture were used for cleaning. By evaluating the photoresist film etch rate, the appropriate process and geometrical conditions for cleaning were obtained. Cleaning of the beam definition aperture, which was contaminated by the electron beam irradiation for 250 hours, was carried out at 0.22 Torr pressure for 20 minutes operation time. The gas flow rate were 200 sccm for O2 and 20 sccm for CF4. Complete removal of the contamination was confirmed.
引用
收藏
页码:67 / 70
相关论文
共 50 条
  • [41] Electron beam-induced current investigation of GaN Schottky diode
    A. Matoussi
    T. Boufaden
    S. Guermazi
    Y. Mlik
    B. El Jani
    A. Toureille
    Journal of Electronic Materials, 2005, 34 : 1059 - 1064
  • [42] Beam-induced damage to thin specimens in an intense electron probe
    Egerton, RF
    Wang, F
    Crozier, PA
    MICROSCOPY AND MICROANALYSIS, 2006, 12 (01) : 65 - 71
  • [43] Effect of electron beam-induced deposition and etching under bias
    Choi, Young R.
    Rack, Philip D.
    Frost, Bernhard
    Joy, David C.
    SCANNING, 2007, 29 (04) : 171 - 176
  • [44] STEM Imaging with Beam-Induced Hole and Secondary Electron Currents
    Hubbard, William A.
    Mecklenburg, Matthew
    Chan, Ho Leung
    Regan, B. C.
    PHYSICAL REVIEW APPLIED, 2018, 10 (04):
  • [45] ELECTRON BEAM-INDUCED POLYMERIZATION OF MONOMERS ON PRECOATED GLASS FIBERS
    NEEDLES, HL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 55 - 55
  • [46] Electron beam-induced changes in vitreous sections of biological samples
    Blanc, NS
    Studer, D
    Ruhl, K
    Dubochet, J
    JOURNAL OF MICROSCOPY, 1998, 192 : 194 - 201
  • [47] Beam-induced electron multipacting with mode resonance in a vacuum chamber
    Cha, H. J.
    de Jauregui, D. Saez
    Grau, A.
    Mueller, A-S
    JOURNAL OF INSTRUMENTATION, 2021, 16 (11):
  • [48] FLUORESCENCE OF ANTHRACENE VAPORS IN ELECTRON BEAM-INDUCED SOLID DISCHARGE
    GRUZINSKII, VV
    KAPUTERKO, MN
    DOKLADY AKADEMII NAUK BELARUSI, 1987, 31 (09): : 809 - 811
  • [49] Electron beam-induced oxygen desorption in γ-LiAlO2
    Hetaba, Walid
    Mogilatenko, Anna
    Neumann, Wolfgang
    MICRON, 2010, 41 (05) : 479 - 483
  • [50] Sidewall angle tuning in focused electron beam-induced processing
    Hari, Sangeetha
    van Dorp, Willem F.
    Mulders, Johannes J. L.
    Trompenaars, Piet H. F.
    Kruit, Pieter
    Hagen, Cornelis W.
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2024, 15 : 447 - 456