Influence of marginal configuration and porcelain addition on the fit of In-Ceram crowns

被引:0
|
作者
Department of Conservative Dentistry, Eastman Dent. Inst. for Oral H., 256 Gray's Inn Road, London WC1X 8LD, United Kingdom [1 ]
机构
来源
BIOMATERIALS | / 19卷 / 1891-1895期
关键词
Ceramic materials - Dental cement - Microscopes - Nondestructive examination - Porcelain - Silicones - Silver;
D O I
暂无
中图分类号
学科分类号
摘要
The fit of In-Ceram copings and crowns was investigated in a laboratory study. Two methods were used, one a direct sectioning technique and the other a cement analogue technique using addition-cured polyvinylsiloxane impression material. The former method involved 40 crowns cemented and sectioned on their respective electroformed silver dies. For the second method, 80 analogues were embedded and sectioned. All measurements were made using a Reflex microscope. This showed In-Ceram crowns and copings to fit well with marginal openings and ranging from 1 to 63 μm and a mean of 19 μm. No significant difference in fit was found between chamfer margins and shoulder margins. The addition of porcelain to the In-Ceram coping and repeated firing cycles involved in building a crown did not alter the fit. It is concluded that In-Ceram crowns fit well in comparison to other crown types.
引用
收藏
相关论文
共 50 条
  • [31] AN INVESTIGATION OF THE FLEXURAL STRENGTH OF IPS-EMPRESS, IN-CERAM AND VITADUR-ALPHA PORCELAIN
    SEOW, L
    WICKENS, J
    MCDONALD, A
    DAVIES, E
    PEARSON, G
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 857 - 857
  • [32] MARGINAL FIT OF CASTABLE CERAMIC CROWNS
    HOLMES, JR
    SULIK, WD
    HOLLAND, GA
    BAYNE, SC
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (05): : 594 - 599
  • [33] MECHANICAL-PROPERTIES AND MICROSTRUCTURE OF IN-CERAM, A CERAMIC-GLASS COMPOSITE FOR DENTAL CROWNS
    HORNBERGER, H
    MARQUIS, PM
    GLASTECHNISCHE BERICHTE-GLASS SCIENCE AND TECHNOLOGY, 1995, 68 (06): : 188 - 194
  • [34] STUDIES ON THE MARGINAL FIT OF DICOR CROWNS
    BIENIEK, KW
    KUPPER, H
    RICHTER, EJ
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1989, 44 (10): : 783 - 784
  • [35] FACTORS AFFECTING THE FIT OF PORCELAIN JACKET CROWNS
    ALKUMRU, H
    HULLAH, WR
    MARQUIS, PM
    WILSON, HJ
    BRITISH DENTAL JOURNAL, 1988, 164 (02) : 39 - 43
  • [36] An up to 5-year clinical evaluation of posterior in-ceram CAD/CAM core crowns
    Bindl, A
    Mörmann, WH
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2002, 15 (05) : 451 - 456
  • [37] An Investigation into the Role of Core Porcelain Thickness and Lamination in Determining the Flexural Strength of In-Ceram Dental Materials
    Alshehri, Sharifa Abdullah
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (04): : 261 - 266
  • [38] STUDIES ON THE CLOSENESS OF THE MARGINAL FIT OF CERAPLATIN CROWNS
    SCHELLER, H
    CZUBAYKO, D
    MESCHEDE, A
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1989, 44 (11): : 896 - 897
  • [39] MARGINAL FIT OF CASTABLE CERAMIC (DICOR) CROWNS
    HOLMES, JR
    BAYNE, SC
    SULIK, WD
    HOLLAND, GA
    JOURNAL OF DENTAL RESEARCH, 1987, 66 : 283 - 283
  • [40] IN-VITRO MARGINAL ADAPTATION OF ALUMINA PORCELAIN CERAMIC CROWNS
    PERA, P
    GILODI, S
    BASSI, F
    CAROSSA, S
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (06): : 585 - 590