Rapid detection of atrial flutter or fibrillation is needed in intensive care or home ECG monitoring with alarm generation, and in portable monitors with warning function, etc. Detection and assessment of these atrial abnormalities is necessary in computerized morphological analysis as well, to decide whether parameter measurements should be rejected, restricted to QRS and/or T wave only, or limited to those leads where atrial flutter or fibrillation waves are less expressed. A method for the detection and measurement of atrial flutter and fibrillation in the T-P segments of the ECG is proposed. An atrial flutter/fibrillation parameter (AFF) is defined as the mean value of the differentiated filtered and rectified signal in these segments. The AFF has been measured in 329 patients from an annotated atrial flutter-fibrillation database. A threshold of AFF=0.35 % with respect to the maximum signal excursion was chosen by a heuristic algorithm, to separate patients with atrial arrhythmia. The accuracy of the method was 91.8 %. The positive and negative detection errors of the AFF classification are discussed.
引用
收藏
页码:217 / 221
相关论文
共 50 条
  • [1] Automatic detection of atrial fibrillation and flutter by wave rectification method
    Christov, I
    Bortolan, G
    Daskalov, I
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (05) : 217 - 221
  • [2] Sequential analysis for automatic detection of atrial fibrillation and flutter
    Christov, I
    Bortolan, G
    Daskalov, I
    COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 293 - 296
  • [3] AUTOMATIC DETECTION OF ATRIAL FIBRILLATION AND FLUTTER A Tachogram-based Algorithm for Mobile Devices
    Kaiser, Stefanie
    Kirst, Malte
    Kunze, Christophe
    BIOSIGNALS 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING, 2009, : 131 - 138
  • [4] A Statistical Approach for Accurate Detection of Atrial Fibrillation and Flutter
    Dash, S.
    Raeder, E.
    Merchant, S.
    Chon, K.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 137 - +
  • [5] Accurate detection of atrial fibrillation and atrial flutter using the electrocardiomatrix technique
    Lee, Veronica
    Xu, Gang
    Liu, Vivian
    Farrehi, Peter
    Borjigin, Jimo
    JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (06) : S121 - S125
  • [6] Automatic Detection Method of Paroxysmal Atrial Fibrillation for Ballistocardiagram Based on CNN
    Jiang F.-F.
    Xu J.-A.
    Li R.
    Xu L.-S.
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2019, 40 (11): : 1539 - 1542and1548
  • [7] A Novel Method to Identify Relevant Features for Automatic Detection of Atrial Fibrillation
    Trardi, Y.
    Ananou, B.
    Haddi, Z.
    Ouladsine, M.
    2018 26TH MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2018, : 613 - 618
  • [8] Automatic atrial fibrillation and flutter detection by a handheld ECG recorder, and utility of sequential finger and precordial recordings
    Brito, Rita
    Mondouagne, Louis-Paulin
    Stettler, Carine
    Combescure, Christophe
    Burri, Haran
    JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (06) : 1135 - 1140
  • [9] The interrelationship between atrial fibrillation and atrial fibrillation and atrial flutter
    Waldo, AL
    PROGRESS IN CARDIOVASCULAR DISEASES, 2005, 48 (01) : 41 - 56
  • [10] Atrial fibrillation and atrial flutter in athletes
    Calvo, Naiara
    Brugada, Josep
    Sitges, Marta
    Mont, Lluis
    BRITISH JOURNAL OF SPORTS MEDICINE, 2012, 46 : 37 - 43