A CO2-controlled ventilation system

被引:0
|
作者
Sodergren, D. [1 ]
机构
[1] Paul Petersson AB, 111 23 Stockholm, Sweden
来源
Environment International | 1982年 / 8卷 / 1-6期
关键词
AIR POLLUTION - Control - CARBON DIOXIDE - CONTROL SYSTEMS;
D O I
暂无
中图分类号
学科分类号
摘要
For buildings in which the emissions from people is the main source of pollution, the number of people is the limiting factor for air ventilation. When such buildings are not used at full capacity, the ventilation, and consequently the energy consumption, is unnecessarily high. One possible control system would allow the amount of CO//2 in the exhaust air to control the ventilation rate. To study if this principle is practicable and economic, a CO//2 indicator has been installed in an office building in Helsinki. The mixture of exterior air and recirculated air is adjusted so that the amount of CO//2 during working hours is kept on 700 ppm. The equipment was used during winter 1981-82, and the variation of CO//2 and the exterior air flow has been registered. The proportion of other pollutants in the room air has been studied simultaneously with a gas chromatography. Different types of CO//2 indicators were used to study the efficiency of the control system.
引用
收藏
页码:483 / 486
相关论文
共 50 条
  • [41] CIRCLE SYSTEM WITHOUT ABSORBER - USE WITH CONTROLLED VENTILATION
    SNOWDON, SL
    POWELL, DL
    FADL, ET
    UTTING, JE
    ANAESTHESIA, 1975, 30 (03) : 323 - 332
  • [42] ASSESSMENT OF BAIN ANESTHETIC SYSTEM DURING CONTROLLED VENTILATION
    HENVILLE, JD
    ADAMS, AP
    BRITISH JOURNAL OF ANAESTHESIA, 1975, 47 (09) : 1024 - 1024
  • [43] Molecular breath-gas analysis by online mass spectrometry in mechanically ventilated patients: a new software-based method of CO2-controlled alveolar gas monitoring
    Dolch, M. E.
    Frey, L.
    Hornuss, C.
    Schmoelz, M.
    Praun, S.
    Villinger, J.
    Schelling, G.
    JOURNAL OF BREATH RESEARCH, 2008, 2 (03)
  • [44] A ventilation system controller based on pressure-drop and CO2 models
    Zucker, Gerhard
    Sporr, Andreas
    Garrido-Marijuan, Antonio
    Ferhatbegovic, Tarik
    Hofmann, Rene
    ENERGY AND BUILDINGS, 2017, 155 : 378 - 389
  • [45] Comparison of responses to CO2 under the conditions of natural respiration and controlled artificial pulmonary ventilation
    Pogodin M.A.
    Granstrem M.P.
    Dimitrienko A.I.
    Human Physiology, 2006, 32 (4) : 440 - 444
  • [46] Environmental effects of pig house ventilation controlled by animal activity and CO2 indoor concentration
    Haeussermann, A
    Hartung, E
    Jungbluth, T
    Precision Livestock Farming '05, 2005, : 57 - 64
  • [47] Comparison of transcutaneous and arterial P-CO2 during controlled ventilation in adult surgical patients
    Biro, P
    Rohling, R
    Kwiatkowski, D
    Weiss, BM
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 : A63 - A63
  • [48] Demand-controlled ventilation -: CO2-based DCV using 62.1-2004
    Taylor, ST
    ASHRAE JOURNAL, 2006, 48 (05) : 67 - +
  • [49] CONTROLLED VENTILATION
    SAKLAD, M
    MODERN TREATMENT, 1969, 6 (01): : 61 - &
  • [50] Dimensionless study on dynamics of pressure controlled mechanical ventilation system
    Yan Shi
    Jinglong Niu
    Maolin Cai
    Weiqing Xu
    Journal of Mechanical Science and Technology, 2015, 29 : 431 - 439