MODEL FOR LIQUID-LIQUID EXTRACTION COLUMN PERFORMANCE - THE INFLUENCE OF DROP SIZE DISTRIBUTION ON EXTRACTION EFFICIENCY.

被引:0
|
作者
Zhang, S.H. [1 ]
Yu, S.C. [1 ]
Zhou, Y.C. [1 ]
Su, Y.F. [1 ]
机构
[1] East-China Inst of Chemical, Technology, Shanghai, China, East-China Inst of Chemical Technology, Shanghai, China
来源
关键词
LIQUIDS - Mixing - MASS TRANSFER - STATISTICAL METHODS;
D O I
暂无
中图分类号
学科分类号
摘要
A precise model for predicting liquid-liquid extraction column efficiency based upon assumed hydrodynamic, axial mixing and mass transfer behavior has been formulated and solved numerically. The complex nature of the dispersed phase can be better described by drop-size-dependent residence time distribution. Both the variation of axial velocities due to drops of different sizes, i. e. forward mixing, and the axial dispersion for the drops of the same size have been considered in this model. The computed results reveal that the effects of both varying velocities and dispersion of drops on extraction efficiency are appreciable and cannot be neglected, and the efficiency may be overestimated if only a forward mixing model is adopted. Refs.
引用
收藏
页码:212 / 226
相关论文
共 50 条
  • [31] Dynamic behaviour and simulation of a liquid-liquid extraction column
    Hufnagl, Harry
    McIntyre, Michael
    Blass, Eckhart
    Chemical Engineering and Technology, 1991, 14 (05): : 301 - 306
  • [32] Hydrodynamics of a cocurrent downward liquid-liquid extraction column
    Samdavid, S.
    Renganathan, T.
    Krishnaiah, K.
    RSC ADVANCES, 2016, 6 (15): : 12430 - 12436
  • [34] OPTIMAL OPERATING POLICY FOR A LIQUID-LIQUID EXTRACTION COLUMN
    PANG, KH
    JOHNSON, AI
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1971, 49 (03): : 398 - &
  • [35] DROP SIZE IN A LIQUID PULSED SIEVE-PLATE EXTRACTION COLUMN
    Usman, M. R.
    Sattar, H.
    Hussain, S. N.
    Muhammad, H.
    Asghar, A.
    Afzal, W.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2009, 26 (04) : 677 - 683
  • [36] DROP SIZE DISTRIBUTION IN AGITATED LIQUID-LIQUID SYSTEMS
    CHEN, HT
    MIDDLEMA.S
    AICHE JOURNAL, 1967, 13 (05) : 989 - +
  • [37] Reproducibility of the hydrodynamic performance and measurements in a liquid-liquid Kuhni extraction column - Relevance to theoretical model evaluation
    Gomes, LN
    Guimaraes, ML
    Lopes, JC
    Madureira, CN
    Stichlmair, J
    Cruz-Pinto, JJ
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (04) : 1061 - 1070
  • [38] Maxwell-Stefan approach coupled with drop population model for the dynamic simulation of liquid-liquid extraction pulsed column
    Toutain, J
    Le Lann, JM
    Gourdon, C
    Joulia, X
    COMPUTERS & CHEMICAL ENGINEERING, 1998, 22 : S379 - S386
  • [39] Study of drop coalescence behavior for liquid-liquid extraction operation
    Department of Chemical Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
    Chem Eng Sci, 1600, 22 (5385-5391):
  • [40] Study of drop coalescence behavior for liquid-liquid extraction operation
    Ban, T
    Kawaizumi, F
    Nii, S
    Takahashi, K
    CHEMICAL ENGINEERING SCIENCE, 2000, 55 (22) : 5385 - 5391