DECOUPLED MODELS FOR LOAD FLOW AND CONTINGENCY EVALUATION.

被引:0
|
作者
Rama Rao, N.
Prasad, K.V.
Seshasai, G.N.
机构
关键词
ELECTRIC POWER SYSTEMS - Load Distribution;
D O I
暂无
中图分类号
学科分类号
摘要
Power system security includes security monitoring, security assessment and control. This paper deals with the security assessment aspect where effects of various credible contingencies such as faults and outages are to be evaluated by fast and reliable means, prior to the occurrence of any one of the contingencies. The paper presents the results of investigations using decoupled models both for regular load flow studies and also for contingency evaluation. Two kinds of decoupled models have been used; one is decoupled Newton load-flow and the other a modification of it. The decoupled model had earlier been used only for load flow analysis whereas in this paper, these models are successfully applied for the analysis of contingencies. The results obtained from the decoupled models have been compared with those from Newton-Raphson and Gauss-Seidal methods. The advantages of decoupled models are pointed out along with the details of convergence characteristics.
引用
收藏
页码:313 / 319
相关论文
共 50 条
  • [31] IMPLEMENTATION OF THE FAST DECOUPLED LOAD FLOW ON A VECTOR COMPUTER
    GOMEZ, A
    BETANCOURT, R
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1990, 5 (03) : 977 - 983
  • [32] 2ND-ORDER DECOUPLED LOAD FLOW
    NANDA, J
    BIJWE, PR
    KOTHARI, DP
    SHENOY, DL
    ELECTRIC MACHINES AND POWER SYSTEMS, 1987, 12 (4-5): : 301 - 312
  • [33] FAST DECOUPLED LOAD FLOW - HYPOTHESIS, DERIVATIONS, AND TESTING
    MONTICELLI, A
    GARCIA, A
    SAAVEDRA, OR
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1990, 5 (04) : 1425 - 1431
  • [34] FAST DECOUPLED LOAD FLOW METHODS IN RECTANGULAR COORDINATES
    SRIVASTAVA, L
    SRIVASTAVA, SC
    SINGH, LP
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1991, 13 (03) : 160 - 166
  • [35] ASSESSMENTS MODELS EVALUATION. A STUDY OF RESULTS AND FACTORS
    Garcia Muniz, Ana Salome
    4TH INTERNATIONAL TECHNOLOGY, EDUCATION AND DEVELOPMENT CONFERENCE (INTED 2010), 2010, : 3359 - 3362
  • [36] Neural models for ozone air quality evaluation.
    Croley, B
    Raasch, E
    Potter, WT
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U476 - U476
  • [37] Load flow and contingency analysis for transmission line outage
    Aeggegn, Dessalegn Bitew
    Salau, Ayodeji Olalekan
    Gebru, Yalew
    ARCHIVES OF ELECTRICAL ENGINEERING, 2020, 69 (03) : 581 - 594
  • [38] NOVEL NONITERATIVE LOAD FLOW FOR VOLTAGE CONTINGENCY ANALYSIS
    SINGH, SN
    KALRA, PK
    SRIVASTAVA, SC
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1994, 16 (01) : 11 - 16
  • [39] IMPROVED DECOUPLED CONTINGENCY SELECTION ALGORITHM
    EKWUE, AO
    SHORT, MJ
    ELECTRIC POWER SYSTEMS RESEARCH, 1991, 20 (03) : 215 - 223
  • [40] FAST-DECOUPLED 3-PHASE LOAD FLOW
    ARRILLAGA, J
    HARKER, BJ