SF6 GAS INSULATED SUBSTATION FOR INDUSTRIAL USE.

被引:0
|
作者
Miwada, Satoshi
Maruyama, Seiichi
Daimon, Goro
Ando, Toshio
机构
来源
Hitachi Review | 1975年 / 24卷 / 07期
关键词
D O I
暂无
中图分类号
TM7 [输配电工程、电力网及电力系统];
学科分类号
080802 ;
摘要
The SF//6 gs insulated substation offers a number of distinct advantages including smaller installation space, higher reliability and labor-saving maintenance and inspection work. However, since the equipment is costlier than that used in conventional type substations, its use has been limited largely to sites subject to severe restrictions as is the case with city substations of power suppliers. Yet, with the concentration of power demand, soaring land prices, and growing construction costs, coupled with needs for maintenance-free operation, there is a rising demand for SF//6 gas insulated substations. Meanwhile, as the conventional isolated-phase type construction is being replaced by a three-phase common tank type construction in a model change for rationalization and size reduction, and a metering outfit for power supply and other special units for general industrial use have been developed, SF//6 gas insulated substations are being considered for use in general industries. Described are the features, construction, protective devices, make-up, and arrangement of a newly developed SF//6 gas insulated substation of the three-phase common tank type designed for general industrial purposes.
引用
收藏
页码:311 / 320
相关论文
共 50 条
  • [11] SF6 GAS INSULATED LOAD INTERRUPTING SWITCHES WITH FUSING
    SCHAFFER, JS
    PATEL, JR
    RUETH, WR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (12): : 3573 - 3577
  • [12] TERMINATION OF HIGH-PRESSURE OIL CABLES IN SF6 GAS-INSULATED MINI-SUBSTATION EQUIPMENT
    GRAYBILL, HW
    KOEHLER, HC
    NADKARNI, JD
    NICHOLAS, JH
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (05): : 1669 - 1674
  • [13] Monitoring of SF6 gas admixtures in gas-insulated electrical equipment
    Paul, Th. A.
    Kramer, A.
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 493 - 496
  • [14] COOLING EFFECT BY GAS-DENSITY OF SF6 GAS INSULATED TRANSFORMER
    SATO, T
    INA, T
    MATSUMOTO, M
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07): : 2229 - 2235
  • [15] A laser photoacoustic system for detection of SF6 in gas insulated systems
    Shwehdi, MH
    Gondal, MA
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 104 - 109
  • [16] NEW APPROACH TO SF6 GAS INSULATED HVDC CONVERTER STATION
    MATSUMURA, S
    TANABE, T
    HARUMOTO, Y
    TOMINAGA, S
    KUWAHARA, H
    NAGAI, N
    TADA, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (09): : 2871 - 2880
  • [17] FACTORS CONTROLLING SURFACE FLASHOVER IN SF6 GAS INSULATED SYSTEMS
    NITTA, T
    SHIBUYA, Y
    FUJIWARA, Y
    ARAHATA, Y
    TAKAHASHI, H
    KUWAHARA, H
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (03): : 959 - 968
  • [18] DC DIELECTRIC STRENGTH OF A SF6 GAS INSULATED SYSTEM.
    Menju, S.
    Takahashi, K.
    1977,
  • [19] Development of monitoring and diagnostic system for SF6 gas insulated switchgear
    Kim, JB
    Kim, MS
    Park, KS
    Song, WP
    Kim, DS
    Kil, GS
    CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 453 - 456
  • [20] SF6 concentration sensor for gas-insulated electrical switchgear
    Paul, Th. A.
    Porus, M.
    Galletti, B.
    Kramer, A.
    SENSORS AND ACTUATORS A-PHYSICAL, 2014, 206 : 51 - 56