CIRCUIT-BREAKER ARC TEST FACILITY.

被引:0
|
作者
Armstrong, J.F.
Seale, T.R.
Stokes, A.D.
机构
关键词
ELECTRIC ARCS; CIRCUIT BREAKING - Photography - LASER BEAMS - Applications - PHOTOGRAPHY - Schlieren System;
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes some of the test facilities available at the University of Sydney for the study of circuit breaker arcs, and summarizes recent progress. The techniques described are being applied to experimental gas-blast interruptors with several aims in mind. The first aim is to improve understanding of the behavior of this type of arc. The results of laser schlieren photography show very clearly that the plasma core of these arcs has an influence which extends to much larger distances than the extent of the strongly visible region and that this, in turn, has a major bearing on the final recovery of dielectric strength following current zero. A second aim has been to build on this understanding to pinpoint specific tests which may be useful on full-scale circuit breakers to give an adequate proof of performance for a wide variety of power-system duties. The ability to make sensitive post-zero current measurements should make it possible to do more than judge performance in terms of a ″go″ or ″no go″ result. Such tests will give a good indication of how close a breaker is to its interruption limit, and in this way improve both the economy of, and information obtained from high-power tests.
引用
下载
收藏
页码:62 / 69
相关论文
共 50 条
  • [31] SYNTHETIC TEST METHODS OF HIGH-DIRECT-CURRENT CIRCUIT-BREAKER
    SHIMADA, R
    TANI, K
    KISHIMOTO, H
    TAMURA, S
    IKEDA, H
    TAMAGAWA, T
    YANABU, S
    MATSUSHITA, T
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1979, 126 (10): : 965 - 970
  • [32] Determination of Circuit-breaker Reliability.
    Hodlova, Miluse
    Elektrotechnicky obzor, 1980, 69 (11): : 678 - 680
  • [33] BODY CURRENT ACTIVATED CIRCUIT-BREAKER
    KREMER, F
    DIMEO, FN
    MOORE, TW
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1975, 22 (05) : 418 - 420
  • [34] FAST CIRCUIT-BREAKER FOR HIGH CURRENTS
    LEROUX, B
    RIOUXDAMIDAU, F
    REVUE DE PHYSIQUE APPLIQUEE, 1979, 14 (07): : 705 - 713
  • [35] Timings of high voltage circuit-breaker
    Rusek, Bartosz
    Balzer, Gerd
    Holstein, Martin
    Claessens, Max-Steffen
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (12) : 2011 - 2016
  • [36] CIRCUIT-BREAKER SCHEDULES AND THEIR APPLICATION IN CALIFORNIA
    GRUBB, WN
    HOACHLANDER, EG
    POLICY ANALYSIS, 1978, 4 (03): : 317 - 337
  • [37] OIL CIRCUIT-BREAKER FOR TODAY - REPLY
    CATON, G
    ELECTRICAL REVIEW, 1972, 190 (26): : 914 - &
  • [38] DEMONSTRATION OF FUSE AND CIRCUIT-BREAKER PRINCIPLES
    BLACKBURN, TR
    THOMPSON, RW
    INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 1980, 17 (02) : 163 - 168
  • [39] The advantages of fixed circuit-breaker switchgear
    Rye, J
    Mackay, LJ
    Tobias, JC
    FIFTH INTERNATIONAL CONFERENCE ON TRENDS IN DISTRIBUTION SWITCHGEAR: 400V-145KV FOR UTILITIES AND PRIVATE NETWORKS, 1998, (459): : 46 - 50
  • [40] CIRCUIT-BREAKER DOUBLES AS POWER SWITCH
    LERRO, JP
    DESIGN NEWS, 1977, 33 (22) : 72 - 73