TRANSIENT RESPONSE OF CURRENT TRANSFORMERS.

被引:0
|
作者
Anon
机构
来源
关键词
ELECTRIC FAULT CURRENTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The asymmetrical component of power-system fault current sometimes causes some degree of saturation of current transformers supplying input current to protective relaying schemes. After saturation occurs, the CT output current will show evidence of distortion and the performance of the protection scheme can be affected. The time-to-saturation, during which time the CT output current is a faithful replica of the primary current, can be readily determined from generally available power-system and CT parameters by using curves presented. The time-to-saturation may be shortened by remanence in the core, and can be lengthened by the use of air gaps. The effect of distorted current is discussed generally according to relay design classes. After the primary fault current ceases, the CT can produce unidirectional decaying output current and can have a high level of flux trapped in the core, both of which can affect the performance of protection schemes.
引用
收藏
相关论文
共 50 条
  • [21] Current feedback in DC/DC converters by using toroidal transformers.
    Sanz, M
    Llombart, A
    Sallan, J
    JOINT CONFERENCE - 1996: IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE & IMEKO TECHNICAL COMMITTEE 7, CONFERENCE PROCEEDINGS, VOLS I AND II: QUALITY MEASUREMENTS: THE INDISPENSABLE BRIDGE BETWEEN THEORY AND REALITY (NO MEASUREMENTS? NO SCIENCE!), 1996, : 560 - 564
  • [22] Buchholz' protection for transformers.
    Thierbach, B
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1927, 71 : 448 - 452
  • [23] DIRECT-CURRENT COMPONENT IN RECTIFIER WINDINGS OF CONVERTER TRANSFORMERS.
    Kraichik, Yu.S.
    Mazurov, M.I.
    Tokmakova, I.A.
    Soviet electrical engineering, 1978, 49 (11): : 83 - 85
  • [24] Silicone Oils for Transformers.
    Perret, J.
    Paris, M.
    Bulletin de la Direction des etudes et recherches. Serie B, Reseaux electriques, materiels electriques, 1987, (02): : 5 - 13
  • [25] LARGE POWER TRANSFORMERS.
    Fryxell, Jorgen
    ASEA Journal (Allmaenna Svenska Elektriska Aktiebolaget), 1984, 57 (04): : 14 - 17
  • [26] Bridges Using Transformers.
    Eugene, C.
    Revue E. Electricite, Electrotechnique Generale, Courants Forts & Applications, 1974, 7 (12): : 316 - 322
  • [27] An alternative method for testing transient response of protective current transformers
    Dampé, JL
    Arrojo, CD
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 254 - 258
  • [28] TRANSIENT COMPENSATION OF CURRENT TRANSFORMERS
    BRADLEY, DA
    GRAY, CB
    OKELLY, D
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (04): : 1264 - 1271
  • [29] CALCULATION OF TRANSIENT CURRENT IN TRANSFORMERS
    AKPINAR, S
    COULSON, M
    SIMPSON, RRS
    SLATER, RD
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1982, 129 (01) : 30 - 34
  • [30] Eddy Current Losses of Metal Compounds in the Stray Magnetic Fluxes of Transformers.
    Kerenyi, Denes
    Elektrotechnika Budapest, 1980, 73 (02): : 49 - 56