Effect of drift eliminator design on cooling tower performance

被引:0
|
作者
Becker, B.R. [1 ]
Burdick, L.F. [1 ]
机构
[1] Univ of Missouri, Kansas City, United States
关键词
Cooling tower performance - Drift eliminator design - Fully instrumented fan test cell - Optimal discharge angle;
D O I
暂无
中图分类号
学科分类号
摘要
In the use of wet cooling towers, drift refers to small droplets of circulating water that are carried out of the cooling tower by the saturated exhaust air. Inertial impaction separators, known as drift eliminators, are used to strip the water droplets from the exhaust air. To achieve peak cooling tower operating efficiency, it is desirable that losses in fan system performance due to the drift eliminators be minimized. Therefore, an experimental program was developed and executed to evaluate the effect of drift eliminator design on cooling tower fan system performance. Flow visualization studies were used to gain insight into the flow patterns within the cooling tower plenum as influenced by drift eliminator design. A fully instrumented fan test cell was used to investigate the effects upon fan system performance resulting from two different styles of drift eliminators. The effect of drift eliminator discharge angle upon fan system total efficiency was investigated and the optimal discharge angle determined.
引用
收藏
页码:632 / 642
相关论文
共 50 条
  • [21] Effect of cooling water salinity on the cooling performance of natural draft wet cooling tower
    Wan, Dawei
    Gao, Shasha
    Liu, Minghua
    Li, Shuguo
    Zhao, Yuanbin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 161
  • [22] Optimization design of thermodynamic performance of horizontal flow cooling tower
    Fang, M.X.
    Kang, Z.G.
    Tang, Y.J.
    Zhongguo Jishui Paishui/China Water & Wastewater, 2001, 17 (10):
  • [23] COMPARISON OF METHODS FOR MEASUREMENT OF COOLING-TOWER DRIFT
    GOLAY, MW
    GLANTSCHNIG, WJ
    BEST, FR
    ATMOSPHERIC ENVIRONMENT, 1986, 20 (02) : 269 - 291
  • [24] SEASONALITY OF COOLING-TOWER DRIFT IN VEGETATION AT ORGDP
    TAYLOR, FG
    WATTS, JA
    PARR, PD
    ENVIRONMENT INTERNATIONAL, 1983, 9 (02) : 149 - 152
  • [25] Effect of Wind on Thermal Performance of Heller Dry Cooling Tower
    Ardekani, Mohammad Ali
    Farhani, Foad
    Mazidi, Mohsen
    JOURNAL OF COMPUTATIONAL APPLIED MECHANICS, 2014, 45 (01): : 1 - 8
  • [26] THE EFFECT OF NONUNIFORM WATER DISTRIBUTION ON COOLING-TOWER PERFORMANCE
    KRANC, SC
    JOURNAL OF ENERGY, 1983, 7 (06): : 636 - 639
  • [27] On the influence of psychrometric ambient conditions on cooling tower drift deposition
    Lucas, M.
    Martinez, P. J.
    Ruiz, J.
    Kaiser, A. S.
    Viedma, A.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (04) : 594 - 604
  • [28] Analysis of drift loss and concentration change of wet cooling tower
    Song, Yu
    Wu, Guangzhong
    Song, Baohong
    2020 THIRD INTERNATIONAL WORKSHOP ON ENVIRONMENT AND GEOSCIENCE, 2020, 569
  • [29] CHROMATED COOLING-TOWER DRIFT AND THE TERRESTRIAL ENVIRONMENT - A REVIEW
    TAYLOR, FG
    NUCLEAR SAFETY, 1980, 21 (04): : 495 - 509
  • [30] Analysis of factors affecting cooling performance of cooling tower
    Yang, Bin
    Sun, Yuanyuan
    Song, Jinchun
    Zhao, Zhouli
    THIRD INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2019, 227