Accurate calibration method for a range finder based on a 3-D model of the optical system

被引:0
|
作者
Ueshiba, Toshio [1 ]
Yoshimi, Takashi [1 ]
Oshima, Masaki [1 ]
机构
[1] Electrotechnical Lab, Tsukuba, Japan
关键词
Calibration - Geometrical optics - Least squares approximations - Light sources - Mathematical models - Mirrors - Optical systems - Parameter estimation - Three dimensional - Video cameras;
D O I
暂无
中图分类号
学科分类号
摘要
Range finding based on the projected light method is superior as a highly reliable means of obtaining dense three-dimensional (3-D) information about scenes. The use of this method, however, demands the development of an accurate calibration method. This paper proposes a method in which the optical system of the range finder is divided into the region surrounding the video camera and the region surrounding the light sources and rotational mirror, and calibration is by the method of least squares. The optical system is modeled in three dimensions and includes geometrical parameters not taken into account in earlier methods such as the torsion of the rotational axis of the mirror. Therefore, this method can be used with the camera and the light source located in any positions. In addition, only a calibration board with a reference pattern is used as a jig. Therefore, highly reliable results are obtained easily because no components other than those of the range finder intervene. This calibration method was applied to the multilight-sources range finder developed by the authors to evaluate its accuracy and to verify its validity.
引用
收藏
页码:16 / 27
相关论文
共 50 条
  • [31] Improved algorithm for the extrinsic calibration of a camera and laser range finder using 3D-3D correspondences
    Ha, Jong-Eun
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2015, 13 (05) : 1272 - 1276
  • [32] A novel temporal calibration method for 3-D ultrasound
    Rousseau, Francois
    Hellier, Pierre
    Barillot, Christian
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (08) : 1108 - 1112
  • [33] Improved algorithm for the extrinsic calibration of a camera and laser range finder using 3D-3D correspondences
    Jong-Eun Ha
    International Journal of Control, Automation and Systems, 2015, 13 : 1272 - 1276
  • [34] An easy and accurate calibration procedure for 3-D shape measurement system based on phase-shifting projected fringe profilometry
    Anchini, R.
    D'Argenio, C.
    Liguor, C.
    Paolillo, A.
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 2044 - 2049
  • [35] Pseudo stereo vision system: Modifications for accurate measurements in 3-D space using camera calibration
    Pachidis, T
    Lygouras, J
    PROCEEDINGS OF THE ISA/IEEE SENSORS FOR INDUSTRY CONFERENCE, 2002, : 66 - 70
  • [36] A method for integrating range images with different resolutions for 3-D model construction
    Morooka, Ken'ichi
    Nagahashi, Hiroshi
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, : 3070 - +
  • [37] Calibration of 3-D measurement system based on a double position sensitive detectors
    Zheng J.
    Li W.
    2018, Tsinghua University (58): : 411 - 416
  • [38] 3-D network model and its parameter calibration
    刘晓宇
    梁乃刚
    李敏
    Science China Mathematics, 2002, (10) : 1351 - 1360
  • [39] 3-D network model and its parameter calibration
    Liu, XY
    Liang, NG
    Li, M
    SCIENCE IN CHINA SERIES A-MATHEMATICS PHYSICS ASTRONOMY, 2002, 45 (10): : 1351 - 1360
  • [40] 3-D network model and its parameter calibration
    Liu Xiaoyu
    Liang Naigang
    Li Min
    Science in China Series A: Mathematics, 2002, 45 (10): : 1351 - 1360