Large area position sensitive X-ray detector for astrophysical observations

被引:0
|
作者
Mels, W.A. [1 ]
Lowes, P. [1 ]
Buurmans, H.B. [1 ]
Brinkman, A.C. [1 ]
Naber, A.P. [1 ]
Rook, A. [1 ]
Zandee, W. [1 ]
机构
[1] Lab for Space Research Utrecht, Netherlands
来源
关键词
Astrophysics; -; Spectrometers; X-Ray - Spectrum Analysis - Telescopes;
D O I
暂无
中图分类号
学科分类号
摘要
A large area position sensitive x-ray detector has been developed for use in the coded mask imaging x-ray spectrometer (COMIS) aboard the USSR research module KVANT. The module was launched on March 31, 1987. The detector, having a sensitive area of 256×256 mm2, is a sealed multiwire proportional counter filled with Xe gas. It covers the photon energy range 2 to 25 kev. At an energy of 6 kev the achieved position resolution is better than 0.6 mm in the direction parallel to the anode wires. The energy resolution is about 18% at 6 kev. The paper gives an overview of the development considerations for optimizing performance with respect to linearity and resolution in energy and position response. Results of performance verification are presented.
引用
收藏
页码:689 / 695
相关论文
共 50 条
  • [41] POSITION-SENSITIVE X-RAY-DETECTOR
    DUVAL, BP
    BARTH, J
    DESLATTES, RD
    HENINS, A
    LUTHER, GG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 274 - 278
  • [42] A new position sensitive area detector for high-speed and high-sensitivity X-ray diffraction analysis
    Taguchi, Takeyoshi
    POWDER DIFFRACTION, 2006, 21 (02) : 97 - 101
  • [43] A large-area, position-sensitive neutron detector with neutron/γ-ray discrimination capabilities
    Zecher, PD
    Galonsky, A
    Kruse, JJ
    Gaff, SJ
    Ottarson, J
    Wang, J
    Deak, F
    Horvath, A
    Kiss, A
    Seres, Z
    Ieki, K
    Iwata, Y
    Schelin, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3): : 329 - 344
  • [44] Lens design for large-area x-ray sensitive vidicons
    Pang, G
    Luhta, R
    Rowlands, JA
    MEDICAL PHYSICS, 1998, 25 (08) : 1533 - 1546
  • [45] Large area x-ray sensitive video camera: Overall feasibility
    Luhta, R
    Rowlands, JA
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 72 - 81
  • [46] Design and experimental study of a two-dimensional position sensitive X-ray detector
    王小胡
    朱启明
    陈元柏
    陈昌
    刘荣光
    王岚
    金艳
    马骁妍
    江山
    中国物理C, 2008, (11) : 903 - 907
  • [47] HIGH-RESOLUTION POSITION-SENSITIVE DETECTOR FOR ULTRAVIOLET AND X-RAY PHOTONS
    RIEGLER, GR
    MORE, KA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 102 - 106
  • [48] Design and experimental study of a two-dimensional position sensitive X-ray detector
    Wang Xiao-Hu
    Zhu Qi-Ming
    Chen Yuan-Bo
    Chen Chang
    Liu Rong-Guang
    Wang Lan
    Jin Yan
    Ma Xiao-Yan
    Jiang Shan
    CHINESE PHYSICS C, 2008, 32 (11) : 903 - 907
  • [49] Conversion of a X-ray position sensitive detector for use in a thermal neutron tomographic system
    Silvani, MI
    Lopes, RT
    de Jesus, EFO
    de Almeida, GL
    Braz, D
    Barbosa, AF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 294 - 299
  • [50] X-ray position-sensitive detector for the energy-dispersive EXAFS spectrometer
    Kovalenko, M
    Mironov, V
    Shaliapin, V
    Tiutiunnikov, S
    JOURNAL OF ALLOYS AND COMPOUNDS, 1999, 286 (1-2) : 26 - 30