MWPC for beta radiochromatography

被引:0
|
作者
Van Eijk, C.W.E. [1 ]
Hollander, R.W. [1 ]
Van der Sluis, S.M. [1 ]
机构
[1] Delft Univ of Technology, Netherlands
来源
关键词
Biomedical Engineering--Chromatographic Analysis - Biomedical Equipment--Radionuclides;
D O I
暂无
中图分类号
学科分类号
摘要
We designed a one-dimensional position sensitive MWPC for the registration of six columns on a 14C beta radiochromatogram of 20×20 cm2 for routine applications. Measuring times have been reduced to 5 min. The spatial resolution is 3 mm FWHM, the position accuracy &le0.5 mm and the intensity accuracy about 5%.
引用
收藏
页码:764 / 766
相关论文
共 50 条
  • [41] MATHEMATICAL-MODELING OF THE PERFORMANCE OF A MWPC
    BELLAZZINI, R
    BREZ, A
    DELGUERRA, A
    MASSAI, MM
    TORQUATI, MR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (01): : 145 - 152
  • [42] USE OF A MULTIWIRE PROPORTIONAL COUNTER (MWPC) FOR TWO-DIMENSIONAL (2D) IMAGING OF BETA-SOURCES
    RAMSDEN, DB
    LOCKETT, SJ
    WOOD, D
    MAUDSLEY, S
    HANHAM, CA
    BRADWELL, AR
    JOURNAL OF ENDOCRINOLOGY, 1986, 108 : 57 - 57
  • [43] APPLICATIONS OF LUMINESCENT COMPOSITIONS IN LIQUID RADIOCHROMATOGRAPHY WITH TRITIUM
    VDOVONKO, VM
    RYSEV, OA
    ZHARKOV, AV
    BOBROVA, VN
    IVANOVA, IF
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY,USSR, 1972, 46 (05): : 678 - &
  • [44] RADIOCHROMATOGRAPHY OF ELIMINATION AND METABOLISM OF METHOPHENAZIN (FRENOLON) IN ANIMAL EXPERIMENTS
    JASZSAGI.E
    ELEKES, I
    PHARMAZIE, 1969, 24 (06): : 337 - &
  • [45] ENHANCED PHOTOEMULSION SENSITIVITY AT LOW TEMPERATURES USED IN RADIOCHROMATOGRAPHY
    KOREN, JF
    MELO, TB
    PRYDZ, S
    JOURNAL OF CHROMATOGRAPHY, 1970, 46 (01): : 129 - &
  • [46] MWPC AS AN ENERGY-LOSS DETECTOR FOR ISR
    FREHSE, H
    HEIDEN, M
    PANTER, M
    PIUZ, F
    NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (1-2): : 97 - 101
  • [47] PERFORMANCE OF A SMALL MWPC BASED PET SYSTEM
    STARIC, M
    KORBAR, D
    STANOVNIK, A
    JOURNAL DE PHYSIQUE IV, 1995, 5 (C1): : 207 - 214
  • [48] An MWPC readout chip for high rate environment
    Kano, H
    Fukunaga, C
    Ikeno, M
    Sasaki, O
    Sato, K
    Matsuura, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 509 - 513
  • [49] Prototype of a large neutron detector based on MWPC
    LiChao Tian
    HuiRong Qi
    ZhiJia Sun
    YanFeng Wang
    Jian Zhang
    RongGuang Liu
    YuBin Zhao
    HongYu Zhang
    DongXu Zhao
    Jing Dong
    Wan Xie
    GuiAn Yang
    Qun Ouyang
    YuanBo Chen
    Science China Physics, Mechanics & Astronomy, 2014, 57 : 2049 - 2053
  • [50] PERFORMANCE OF A HYBRID MWPC-DRIFT CHAMBER
    MAURER, GS
    CARREIRA, EM
    CRANNELL, H
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (04): : 631 - 631