Hollow blade agitator for mass transfer in gas-liquid bioreactors

被引:0
|
作者
机构
[1] Linek, V.
[2] Benes, P.
[3] Sinkule, J.
来源
Linek, V. | 1600年 / 69期
关键词
Turbomachinery; -; Impellers; Water;
D O I
暂无
中图分类号
学科分类号
摘要
Power input and kLa values for a hollow blade turbine (H-turbine) and for a Rushton disc flat blade turbine (R-turbine) were measured in water (coalescent liquid) and 0.5 M Na2SO4 solution (noncoalescent liquid). The results show that a simple exchange of the R-turbine for the H-turbine, for the same impeller speed and gas flow rate, brings no improvement in kLa. The exchange of the turbines under the same gassed power level brings an insignificant decrease of kLa (ca 10%) in coalescent liquid, while in noncoalescent liquid both turbines give roughly the same kLa values at a power input lower than 1 kW/m3. For higher power inputs the kLa values of the H-turbine are significantly decreased (up to 60% at 5 kW/m3). When the ungassed power is kept constant, the exchange allows an increase in kLa by 30 to 60% in coalescent liquids. This increase is, however, realized at the expense of higher power demand (by 80 to 150%) of the H-turbine when aerated. In a noncoalescent liquid at low impeller speed (I) the exchange brings a substantial improvement of kLa (80 to 110%) at the expense of higher gassed power level (60-90%). At a higher impeller speed the power input of the H-turbine strongly increases (up to 140%) while the increase in kLa is only 60%. The exchange is then disadvantageous.
引用
收藏
相关论文
共 50 条
  • [21] Characteristics of the gas-liquid mass transfer in a horizontal polymerization reactor with a broad-blade stirrer
    Bai, Wei-Min
    Cao, Gui-Ping
    Su, Xiao-Li
    Zhang, Ming-Hua
    Huadong Ligong Daxue Xuebao /Journal of East China University of Science and Technology, 2008, 34 (02): : 154 - 158
  • [22] Experimental study on gas-liquid dispersion and mass transfer of dislocated-blade Rushton impeller
    Ran S.-H.
    Zhou S.-J.
    Yang F.-L.
    Li B.
    Zhou, Shen-Jie (zhousj@sdu.edu.cn), 1600, Zhejiang University (51): : 1368 - 1373
  • [23] A NOVEL TECHNIQUE BASED ON KR-85 FOR QUANTIFICATION OF GAS-LIQUID MASS-TRANSFER IN BIOREACTORS
    PEDERSEN, AG
    ANDERSEN, H
    NIELSEN, J
    VILLADSEN, J
    CHEMICAL ENGINEERING SCIENCE, 1994, 49 (06) : 803 - 810
  • [24] Implementation of Perforated Concentric Ring Walls Considerably Improves Gas-Liquid Mass Transfer of Shaken Bioreactors
    Hansen, Sven
    Gumprecht, Andreas
    Micheel, Linda
    Hennemann, Hans-Georg
    Enzmann, Franziska
    Bluemke, Wilfried
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [25] DEPENDENCE OF GAS-LIQUID MASS-TRANSFER ON STRUCTURE AND HYDRODYNAMICS OF BIOREACTORS WITH LOW-DENSITY BIOPARTICLES
    SISAK, C
    KOMAROMY, P
    SZAJANI, B
    HUNGARIAN JOURNAL OF INDUSTRIAL CHEMISTRY, 1994, 22 (04): : 309 - 313
  • [26] Interfacial gas-liquid mass transfer modelling
    George, J
    AIR POLLUTION IV: MONITORING, SIMULATION AND CONTROL, 1996, : 287 - 296
  • [27] MASS-TRANSFER IN GAS-LIQUID FLOW
    TISHIN, VB
    LEPILIN, VN
    IBRAGIMOVA, LN
    IVANOVA, TY
    NOVOSELOV, AG
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1982, 55 (04): : 853 - 855
  • [28] Mass transfer in gas-liquid flow in microchannels
    Yue, Jun
    Chen, Guangwen
    Yuan, Quan
    Luo, Ling'ai
    le Gall, Hervé
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2006, 57 (06): : 1296 - 1303
  • [29] MASS TRANSFER IN GAS-LIQUID CONTACTING SYSTEMS
    SIDEMAN, S
    HORTACSU, O
    FULTON, JW
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1966, 58 (07): : 32 - &
  • [30] MASS TRANSFER GAS-LIQUID IN COLUMN OF AERATION
    Salla, Marcio Ricardo
    Schulz, Harry Edmar
    ENGENHARIA SANITARIA E AMBIENTAL, 2008, 13 (02) : 189 - 197