A continuous-flow denuder for the measurement of ambient concentrations and surface-exchange fluxes of ammonia

被引:0
|
作者
Wyers, G.P. [1 ]
Otjes, R.P. [1 ]
Slanina, J. [1 ]
机构
[1] Energy Research Foundation ECN, PO Box 1, 1755 ZG Petten, Netherlands
来源
关键词
Air pollution - Ammonia - Gas absorption - Meteorological instruments - Sensors;
D O I
暂无
中图分类号
学科分类号
摘要
A new diffusion denuder is described for the continuous measurement of atmospheric ammonia. Ammonia is collected in an absorption solution in a rotating denuder, separated from interfering compounds by diffusion through a semi-permeable membrane and detected by conductometry. The method is free from interferences by other atmospheric gases, with the exception of volatile amines. The detection limit is 6 ng m-3 for a 30-min integration time. This compact instrument is fully automated and suited for routine deployment in field studies. The precision is sufficiently high for micrometeorological studies of air-surface exchange of ammonia.
引用
收藏
页码:2085 / 2090
相关论文
共 50 条
  • [31] CONTINUOUS-FLOW FLUOROMETRY OF LOW GALACTOSE CONCENTRATIONS IN BLOOD OR PLASMA
    HENDERSON, JM
    FALES, FW
    CLINICAL CHEMISTRY, 1980, 26 (02) : 282 - 285
  • [32] Arsenic uptake by pyrite at ambient environmental conditions: A continuous-flow experiment
    Wolthers, M
    Butler, IB
    Rickard, D
    Mason, PRD
    ADVANCES IN ARSENIC RESEARCH: INTEGRATION OF EXPERIMENTAL AND OBSERVATIONAL STUDIES AND IMPLICATIONS FOR MITIGATION, 2005, 915 : 60 - 76
  • [33] REACTIONS OF ACETYLENE AND AMMONIA IN A CONTINUOUS-FLOW MICROWAVE DISCHARGE REACTOR.
    Brooks, Brian W.
    Spearot, Rebecca M.
    1975, 25 (04): : 279 - 288
  • [34] CONTINUOUS-FLOW PLASMA EXCHANGE IN TREATMENT OF HOMOZYGOUS FAMILIAL HYPERCHOLESTEROLEMIA
    BERGER, GMB
    MILLER, JL
    BONNICI, F
    JOFFE, HS
    DUBOVSKY, DW
    AMERICAN JOURNAL OF MEDICINE, 1978, 65 (02): : 243 - 251
  • [35] CONTINUOUS-FLOW EXCHANGE-PLASMAPHERESIS IN SEVERE RHESUS ISOIMMUNISATION
    POLE, JRG
    BARR, W
    WILLOUGHBY, ML
    LANCET, 1974, 1 (7865): : 1051 - 1051
  • [36] MEASUREMENTS OF CONCENTRATIONS AND DRY SURFACE FLUXES OF ATMOSPHERIC NITRATES IN THE PRESENCE OF AMMONIA
    HUEBERT, BJ
    LUKE, WT
    DELANY, AC
    BROST, RA
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1988, 93 (D6): : 7127 - 7136
  • [37] A Continuous Flow System for the Measurement of Ambient Nitrogen Oxides [NO
    Malingappa, Pandurangappa
    Yarradoddappa, Venkataramanappa
    ANALYTICAL CHEMISTRY INSIGHTS, 2014, 9 : 67 - 73
  • [38] MEASUREMENT OF HDL CHOLESTEROL BY AN AUTOMATIC METHOD ADAPTED TO CONTINUOUS-FLOW
    RAICHVARG, D
    TALLET, F
    LEFEVRE, G
    CANAL, J
    ANNALES DE BIOLOGIE CLINIQUE, 1982, 40 (01) : 55 - 55
  • [39] Measurement of enzyme kinetics using a continuous-flow microfluidic system
    Seong, GH
    Heo, J
    Crooks, RM
    ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3161 - 3167