A continuous-flow denuder for the measurement of ambient concentrations and surface-exchange fluxes of ammonia

被引:0
|
作者
Wyers, G.P. [1 ]
Otjes, R.P. [1 ]
Slanina, J. [1 ]
机构
[1] Energy Research Foundation ECN, PO Box 1, 1755 ZG Petten, Netherlands
来源
关键词
Air pollution - Ammonia - Gas absorption - Meteorological instruments - Sensors;
D O I
暂无
中图分类号
学科分类号
摘要
A new diffusion denuder is described for the continuous measurement of atmospheric ammonia. Ammonia is collected in an absorption solution in a rotating denuder, separated from interfering compounds by diffusion through a semi-permeable membrane and detected by conductometry. The method is free from interferences by other atmospheric gases, with the exception of volatile amines. The detection limit is 6 ng m-3 for a 30-min integration time. This compact instrument is fully automated and suited for routine deployment in field studies. The precision is sufficiently high for micrometeorological studies of air-surface exchange of ammonia.
引用
收藏
页码:2085 / 2090
相关论文
共 50 条
  • [1] A CONTINUOUS-FLOW DENUDER FOR THE MEASUREMENT OF AMBIENT CONCENTRATIONS AND SURFACE-EXCHANGE FLUXES OF AMMONIA
    WYERS, GP
    OTIES, RP
    SLANINA, J
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (13): : 2085 - 2090
  • [2] Intercalibration of a passive wind-vane flux sampler against a continuous-flow denuder for the measurements of atmospheric ammonia concentrations and surface exchange fluxes
    Hansen, B
    Wyers, GP
    Nornberg, P
    Nemitz, E
    Sutton, MA
    ATMOSPHERIC ENVIRONMENT, 1999, 33 (27) : 4379 - 4388
  • [3] Ammonia surface-exchange above an agricultural field in southeast England
    Yamulki, S
    Harrison, RM
    Goulding, KWT
    ATMOSPHERIC ENVIRONMENT, 1996, 30 (01) : 109 - 118
  • [4] Performance characteristics for the determination of ammonia concentrations in ambient air - Part 1: denuder measurements
    Daemmgen, U.
    Thoeni, L.
    Lumpp, R.
    Gilke, K.
    Seitler, E.
    Bullinger, M.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2010, 70 (05): : 197 - 201
  • [5] Apparatus for continuous-flow underway spectrophotometric measurement of surface water pH
    Tapp, M
    Hunter, K
    Currie, K
    Mackaskill, B
    MARINE CHEMISTRY, 2000, 72 (2-4) : 193 - 202
  • [6] MEASUREMENT OF MAGNESIUM BY CONTINUOUS-FLOW COLORIMETRY
    FOWLER, RT
    ABERNETHY, MH
    WALMSLEY, TA
    TAYLOR, HW
    CLINICAL CHEMISTRY, 1982, 28 (03) : 523 - 525
  • [7] On the measurement of stagnancy in continuous-flow systems
    Nauman, EB
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (02) : 304 - 308
  • [8] CONTINUOUS-FLOW MEASUREMENT OF DESORPTION ISOTHERMS
    KARP, S
    MUSTACCI.A
    LOWELL, S
    ANALYTICAL CHEMISTRY, 1972, 44 (14) : 2395 - &
  • [9] RAPID PLASMA EXCHANGE WITH CONTINUOUS-FLOW CENTRIFUGE
    MCCULLOUGH, J
    FORTUNY, IE
    KENNEDY, BJ
    EDSON, JR
    BRANDA, RF
    JACOB, HS
    TRANSFUSION, 1973, 13 (02) : 94 - 99
  • [10] CONTINUOUS-FLOW REDUCTION OF NITRATE TO AMMONIA WITH ANTIGRANULOCYTES ZINC
    CARLSON, RM
    ANALYTICAL CHEMISTRY, 1986, 58 (07) : 1590 - 1591