Magnetic field exposure device for patch-clamp measuring system

被引:0
|
作者
Obo, M.
Otaka, Y.
Kitamura, S.
机构
关键词
Electric currents - Function generators - Magnetic field effects - Microscopic examination;
D O I
暂无
中图分类号
学科分类号
摘要
A device was developed that enables in situ optical and electrical observations of a single cell under exposure to a magnetic field. Electric current through a flat conductor sheet made a homogeneous magnetic field above the sheet. The sheet was made of brass, 30 mm × 30 mm to 60 mm × 660 mm and 0.3 mm thick, with a hole 2 mm in diameter in the center of the sheet for the light path of a microscope. An electric current of diverse waveforms was supplied by a function generator through an amplifier, generating a magnetic field of the same waveform up to 0.14 mT. The sheet was laid concentrically on the stage of a microscope. The homogeneity of the field over a 40 mm × 40 mm sheet was estimated to be 5% in the vertical and 0.1% in the horizontal directions for a 1 mm shift of a cell. A sheet does not hinder movement of the patch-clamp attachments and leaves space for a pair of coils to compensate the geomagnetic field on the stage of the microscope. The electric noise caused by the field was so small that it could be canceled in the data collection process.
引用
收藏
页码:197 / 202
相关论文
共 50 条
  • [1] TRI-AXIAL MAGNETIC FIELD EXPOSURE SYSTEM FOR A PATCH-CLAMP SET-UP
    Gavoci, E.
    Procopio, M. G.
    Mesirca, P.
    Kuqi, Dh.
    Zironi, I.
    Remondini, D.
    Ahmetaga, Sh.
    Bersani, F.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2013, 14 (03): : 1115 - 1122
  • [2] Effect of magnetic field exposure on calcium channel currents using patch-clamp technique
    Yasui, M
    Kikuchi, T
    Ooba, W
    Obo, M
    Konishi, S
    Otaka, Y
    ELECTRICITY AND MAGNETISM IN BIOLOGY AND MEDICINE, 1999, : 581 - 584
  • [3] A SIMPLE DEVICE FOR PATCH-CLAMP MEASUREMENTS
    MARKO, M
    ZACHAR, J
    ZAHRADNIK, I
    ZAHRADNIKOVA, A
    PHYSIOLOGIA BOHEMOSLOVACA, 1985, 34 (05): : 441 - 442
  • [4] An integrated planar patch-clamp system
    Pandey, S
    White, MH
    2001 INTERNATIONAL SEMICONDUCTOR DEVICE RESEARCH SYMPOSIUM, PROCEEDINGS, 2001, : 170 - 173
  • [5] Sperm Patch-Clamp
    Lishko, Polina
    Clapham, David E.
    Navarro, Betsy
    Kirichok, Yuriy
    CILIA, PT B, 2013, 525 : 59 - 83
  • [6] THE PATCH-CLAMP TECHNIQUE
    LIEM, LK
    SIMARD, JM
    SONG, YM
    TEWARI, K
    NEUROSURGERY, 1995, 36 (02) : 382 - 392
  • [7] Patch-clamp techniques
    Teulon, J
    M S-MEDECINE SCIENCES, 2004, 20 (05): : 550 - 550
  • [8] An Integrated Patch-Clamp System with Dual Input
    Weerakoon, Pujitha
    Sigworth, Fred
    Kindlmann, Peter
    Santos-Sacchi, Joseph
    Yang, Youshan
    Culurciello, Eugenio
    2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 1523 - 1526
  • [9] A simple perfusion system for patch-clamp studies
    Vorobjev, VS
    Sharonova, IN
    Haas, HL
    JOURNAL OF NEUROSCIENCE METHODS, 1996, 68 (02) : 303 - 307
  • [10] A patch-clamp device with integrated actuators for cell selection and positioning
    Gong, Zhongcheng
    Nagarajan, Krithika
    Penmetsa, Siva
    Mills, David
    Que, Long
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 278 - +