X-RAY DETECTOR CALIBRATIONS IN THE 280-eV TO 100-keV ENERGY RANGE.

被引:0
|
作者
Gaines, J.L.
Kuckuck, R.W.
Ernst, R.D.
机构
来源
| 1976年
关键词
X-rays;
D O I
暂无
中图分类号
学科分类号
摘要
The absolute sensitivity for several different types of radiation detectors has been measured using x-rays in the energy range of 280 eV to 100 keV. The photons in this energy range are produced using three separate x-ray-generating facilities. The detectors include a silicon semiconductor, two photoelectric diode detectors employing aluminum and gold photocathodes, and three detectors incorporating plastic scintillators and photodiodes. The plastic scintillators were MEL-150C, Pilot B, and NE102.
引用
收藏
页码:75 / 78
相关论文
共 50 条
  • [21] X-RAY MULTILAYER MIRRORS WITH WIDE ANGULAR RANGE.
    Kalnov, V. A.
    Protopopov, V. V.
    Valiev, K. A.
    Imamov, R. M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C470 - C470
  • [22] OPTIMUM ZONE PLATES FOR THE SOFT X-RAY RANGE.
    Tatchyn, Roman
    Csonka, P.L.
    Lindau, I.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1983, 222 (1-2) : 51 - 59
  • [23] Energy dispersion of X-ray continua in the energy range 8 keV to 16 keV by refraction on Si wafers
    Ebel, H
    Streli, C
    Pepponi, G
    Wobrauschek, P
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2045 - 2048
  • [24] A GE SOLID-STATE DETECTOR AS AN X-RAY FILTER WITH A 5 EV BANDPASS AT 11.1 KEV
    SCHULKE, W
    MOURIKIS, S
    LIEDTKE, KD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 266 - 269
  • [25] RESULTS OF AN X-RAY SCANNING OF SKY IN 20 - 200 KEV ENERGY RANGE
    BRINI, D
    CATTANI, D
    CIRIEGI, U
    FULIGNI, F
    GALLI, M
    GANDOLFI, A
    MORETTI, E
    SACCHI, C
    ANNALES D ASTROPHYSIQUE, 1965, 28 (06): : 1034 - &
  • [26] COSMIC X-RAY SOURCES IN 20-180 KEV ENERGY RANGE
    BRINI, D
    CIRIEGI, U
    FULIGNI, F
    MORETTI, E
    VESPIGNA.G
    ASTROPHYSICAL JOURNAL, 1967, 149 (2P1): : 429 - &
  • [27] Application of CdTe Detector for Determining Uranium Enrichment on 89–100 keV γ- and X-ray Radiation
    S. M. Brodsky
    Atomic Energy, 2013, 114 : 421 - 427
  • [28] Superfine photon-counting detector for 0.1-100 keV X-ray imaging
    Miyata, E
    Tawa, N
    Mukai, K
    Miki, A
    Koizumi, G
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 56 - 65
  • [29] X-RAY STANDING WAVES AND X-RAY PHOTOEMISSION MEASUREMENTS IN THE ENERGY-RANGE 2.7-7 KEV
    DRUBE, W
    LESSMANN, A
    MATERLIK, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1138 - 1141
  • [30] Dosimetric properties of high energy current (HEC) detector in keV x-ray beams
    Zygmanski, Piotr
    Shrestha, Suman
    Elshahat, Bassem
    Karellas, Andrew
    Sajo, Erno
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07): : N121 - N129