X-RAY DETECTOR CALIBRATIONS IN THE 280-eV TO 100-keV ENERGY RANGE.

被引:0
|
作者
Gaines, J.L.
Kuckuck, R.W.
Ernst, R.D.
机构
来源
| 1976年
关键词
X-rays;
D O I
暂无
中图分类号
学科分类号
摘要
The absolute sensitivity for several different types of radiation detectors has been measured using x-rays in the energy range of 280 eV to 100 keV. The photons in this energy range are produced using three separate x-ray-generating facilities. The detectors include a silicon semiconductor, two photoelectric diode detectors employing aluminum and gold photocathodes, and three detectors incorporating plastic scintillators and photodiodes. The plastic scintillators were MEL-150C, Pilot B, and NE102.
引用
收藏
页码:75 / 78
相关论文
共 50 条
  • [1] X-RAY DETECTOR CALIBRATIONS IN 185 EV-932 EV ENERGY-RANGE
    GAINES, JL
    KUCKUCK, RW
    ERNST, RD
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (11): : 1329 - 1329
  • [2] X-ray spectroscopy and calibrations in the 50 eV to 60 keV range
    Seely, J
    Feldman, U
    Weaver, J
    Hudson, L
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 245 - 248
  • [3] X-ray spectroscopy and calibrations in the 50 eV to 60 keV range
    Seely, JF
    Hudson, LT
    Weaver, JL
    Holland, GE
    Boyer, CN
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS IV, 2002, 4786 : 183 - 188
  • [4] CdZnTe x-ray detector for 30 similar to 100 keV energy
    Yoo, SS
    Rodricks, B
    Shastri, SD
    Montano, PA
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 50 - 56
  • [5] Precise Calibration and Application of Hard X-Ray Detector in Energy Range of 10-100 keV
    He Xiaoan
    Yi Rongqing
    Li Chaoguang
    Chen Bolun
    Li Fan
    Zheng Jianhua
    Xue Yanlin
    Wang Feng
    ACTA OPTICA SINICA, 2022, 42 (11)
  • [6] X-RAY EMISSION IN ENERGY RANGE 100 EV - 1000 EV1)
    VANARK, HJ
    VANDEROT.J
    VAKUUM-TECHNIK, 1968, 17 (07): : 173 - &
  • [7] STATE-OF-THE-ART EFFICIENCY DETERMINATION FOR A Si(Li) X-RAY DETECTOR IN THE 3-40 KEV ENERGY RANGE.
    Campbell, J.L.
    McGhee, P.L.
    Nuclear instruments and methods in physics research, 1986, A248 (2-3): : 393 - 404
  • [8] X-RAY DIAGNOSTICS 100 EV-1 KEV
    KORNBLUM, HN
    KOPPEL, LN
    LEIPELT, GR
    SLIVINSKY, VW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (09): : 1078 - 1078
  • [9] Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range
    Szabo, Csilla I.
    Feldman, Uri
    Seltzer, Stephen
    Hudson, Lawrence T.
    O'Brien, Michelle
    Park, Hye-Sook
    Seely, John F.
    OPTICS LETTERS, 2011, 36 (08) : 1335 - 1337
  • [10] PULSED HIGH-INTENSITY X-RAY SOURCE FOR DETECTOR CALIBRATIONS AT 1.5 KEV
    SPARROW, JH
    DICK, CE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 519 - 519