VOLUME MEASUREMENT IN VIVO USING POSITRON TOMOGRAPHY.

被引:0
|
作者
Townsend, D.
Frey, P.
Donath, A.
Clack, R.
Schorr, B.
Jeavons, A.
机构
关键词
CAMERAS - IMAGING TECHNIQUES;
D O I
暂无
中图分类号
学科分类号
摘要
The high density avalanche chamber (HIDAC) positron camera has been used for tomographic imaging of the human thyroid in vivo. Images are made seven and twenty-four hours after oral adminstration to the patient of the positron-emitting radionuclide **1**2**4I. As a consequence of the high spatial resolution of the camera (2. 5 mm fwhm), the functional volume of the thyroid may be estimated from the tomographic images to within about 12%. This paper discusses some of the studies performed to ensure reconstructed images free from artifacts and distortions, and, as illustration of the technique, two typical patient cases are presented.
引用
收藏
相关论文
共 50 条
  • [41] FPGA-Based Pulse Parameter Discovery for Positron Emission Tomography.
    Haselman, M.
    Hauck, S.
    Lewellen, T. K.
    Miyaoka, R. S.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2956 - +
  • [42] BaF2-MWPC GAMMA CAMERA FOR POSITRON EMISSION TOMOGRAPHY.
    Schotanus, P.
    Van Eijk, C.W.E.
    Hollander, R.W.
    Nuclear instruments and methods in physics research, 1987, A269 (02): : 377 - 384
  • [43] A polymorphism of the serotonin transporter gene affects in vivo expression of transporter in human raphe nuclei as measured by positron emission tomography.
    Mann, JJ
    Huang, YY
    Arango, V
    Oquendo, MA
    Hastings, R
    Van Heertum, RL
    Parsey, RV
    NEUROIMAGE, 2004, 22 : T47 - T48
  • [44] Myocardial flow reserve in human infants measured by positron emission tomography.
    Donnelly, JP
    Raffel, D
    Shulkin, BL
    Corbett, JI
    Bove, EL
    Mosca, RS
    Kulik, TJ
    PEDIATRIC RESEARCH, 1996, 39 (04) : 145 - 145
  • [45] Mapping nephron mass in vivo using positron emission tomography
    Baldelomar, Edwin J.
    Reichert, David E.
    Shoghi, Kooresh, I
    Beeman, Scott C.
    Charlton, Jennifer R.
    Strong, Lori
    Fettig, Nikki
    Klaas, Amanda
    Bennett, Kevin M.
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2021, 320 (02) : F183 - F192
  • [46] Ex Vivo Lung Volume Measurement Using High Resolution Micro-Computerized Tomography
    Luo, J.
    Varghese, B.
    Skorka, T.
    Zhou, B.
    Crandall, E. D.
    Borok, Z.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [47] Investigation of LSO crystals for high spatial resolution positron emission tomography.
    Casey, ME
    Eriksson, L
    Schmand, M
    Andreaco, MS
    Paulus, M
    Dahlbom, M
    Nutt, R
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1029 - 1033
  • [48] In Vivo Measurement of the Human Vitreous Chamber Volume Using Computed Tomography Imaging of 100 Eyes
    Azhdam, Ariel M.
    Goldberg, Robert A.
    Ugradar, Shoaib
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (01):
  • [49] Microtomograph prototype positron emission tomography. Spatial resolution and metabolic studies
    Alva-Sanchez, H.
    Murrieta, T.
    Ruiz-Trejo, C.
    Brandan, M. E.
    Martinez-Davalos, A.
    Rodriguez-Villafuerte, M.
    REVISTA MEXICANA DE FISICA, 2010, 56 (02) : 175 - 182
  • [50] Improved separations in the production of yttrium-86 for positron emission tomography.
    Shoner, SC
    Eary, JF
    Krohn, KA
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 232P - 232P