Development of a membrane oxygenator driven by a pneumatic pulse pump

被引:0
|
作者
Hashimoto, Shigehiro
Tominaga, Seiichi
Yoshida, Minoru
Sasaki, Yasunori
机构
关键词
Biomechanics - Biomedical engineering - Blood - Equipment testing - Flow control - Fluid mechanics - Pneumatic control equipment - Reciprocating pumps;
D O I
暂无
中图分类号
学科分类号
摘要
A new membrane oxygenator combined with a reciprocating pump was designed to shorten the extracorporeal circulation circuit and to increase the efficiency of oxygenation. At a polycarbonate cylinder, 1 700 silicone tubes were bundled and packed among elastic silicone filler. In both inflow and outflow sides of the cylinder, ball valves were equipped. The total available area of the membrane was 8.8×10-2 m2. The membrane was pneumatically driven with a reciprocating pump in performance tests, in which 100% oxygen circulated in the gas side. The mock test shows that the partial pressure of oxygen increases from 1.57×104 Pa at the inlet to 4.72×104 Pa at the outlet of the oxygenator when 2.0×10-7 m3 s-1 saline solution is pumped. The performance has been maintained in animal tests.
引用
收藏
页码:491 / 495
相关论文
共 50 条
  • [21] DEVELOPMENT OF A MEMBRANE OXYGENATOR - OVERCOMING BLOOD DIFFUSION LIMITATION
    BARTLETT, RH
    KITTREDGE, D
    NOYES, BS
    WILLARD, RH
    DRINKER, PA
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (06): : 795 - +
  • [22] TOWARD DEVELOPMENT OF A NEONATAL PULMONARY ASSIST MEMBRANE OXYGENATOR
    HUNG, TK
    BOROVETZ, HS
    HARDESTY, RL
    WEISSMAN, MH
    SOUTH AFRICAN MECHANICAL ENGINEER, 1978, 28 (04): : 112 - 116
  • [23] LANDE-EDWARDS MEMBRANE OXYGENATOR WITHOUT PUMP AS TOTAL LUNG PROSTHESIS
    VANDERHOEFT, P
    DERKS, C
    FRANCQUEN, PD
    ROZENCWAJG, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1975, 69 (02): : 196 - 202
  • [24] DEVELOPMENT OF A SILICON HOLLOW FIBER MEMBRANE-OXYGENATOR
    YADA, I
    MORIMOTO, T
    KUSAGAWA, M
    ARTIFICIAL ORGANS, 1981, 5 (03) : 324 - 325
  • [25] Experimental use of a compact centrifugal pump and membrane oxygenator as a cardiopulmonary support system
    Suenaga, E
    Naito, K
    Cao, ZL
    Suda, H
    Ueno, T
    Natsuaki, M
    Itoh, T
    ARTIFICIAL ORGANS, 2000, 24 (11) : 912 - 915
  • [26] Postpartum myocardial infarction rescued with an intraaortic balloon pump and extracorporeal membrane oxygenator
    Ko, WJ
    Ho, HN
    Chu, SH
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1998, 63 (01) : 81 - 84
  • [27] PHYSIOLOGICAL STUDIES WITH A PUMP - OXYGENATOR
    GOLLAN, F
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1956, 1 : 78 - &
  • [28] HEMOLYSIS IN PUMP OXYGENATOR UNITS
    WANDALL, HH
    SIVERTSE.U
    MOLLER, S
    CHRISTEN.EJ
    BINDSLEV, A
    EUROPEAN SURGICAL RESEARCH, 1972, 4 (4-5) : 368 - 368
  • [29] LIQUID MEMBRANE OXYGENATOR
    WALLACE, HW
    ASHER, WJ
    ZUBROW, MT
    STEIN, TP
    BROOKS, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1973, 66 (06): : 887 - 893
  • [30] SILICONE MEMBRANE OXYGENATOR
    DRINKER, PA
    BARTLETT, RH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1974, 68 (06): : 976 - 976