READOUT OF OPTICAL SCINTILLATION FIBRES BY A POSITION-SENSITIVE PHOTOMULTIPLIER.

被引:0
|
作者
Kuroda, K.
Nemoz, C.
Penzo, A.
Poulet, M.
Sillou, D.
机构
来源
关键词
OPTICAL FIBERS - Scintillation - PHYSICS - High Energy;
D O I
暂无
中图分类号
学科分类号
摘要
The present status of a position-sensitive photomultiplier is surveyed, with the aim of applying such a device to a high-rate apparatus in combination with optical scintillation fibers. A spatial resolution of approximately 1. 1 mm (fwhm), obtained with a single fiber of 1 mm diameter, would allow the setting up of a linear array, 180 mm wide, with a spatial resolution of approximately equals 1mm which can be read out by a single photomultiplier tube of this type. Also presented are the important improvements foreseen for the present tubes, based on the scaling property of the Lorentz equation describing the motion of electrons.
引用
收藏
页码:114 / 119
相关论文
共 50 条
  • [31] HODOSCOPE READOUT SYSTEM AND OPTICAL BINARY CODED POSITION-SENSITIVE RADIATION DETECTOR
    LEE, LY
    ALLRED, JC
    GOODMAN, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 719 - 719
  • [32] Simulation of the Optical Parameters of Position-Sensitive Scintillation Detectors with an Organic Light Guide
    D. N. Trunov
    V. N. Marin
    R. A. Sadykov
    E. V. Altynbaev
    T. I. Glushkova
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2023, 17 : 468 - 472
  • [33] Simulation of the Optical Parameters of Position-Sensitive Scintillation Detectors with an Organic Light Guide
    Trunov, D. N.
    Marin, V. N.
    Sadykov, R. A.
    Altynbaev, E. V.
    Glushkova, T. I.
    JOURNAL OF SURFACE INVESTIGATION, 2023, 17 (02): : 468 - 472
  • [34] Characterisation of a position-sensitive photomultiplier tube for MicroPET detection modules
    Alva, H.
    Rodriguez-Villafuerte, M.
    Martinez-Davalos, A.
    Moreno, E.
    Hernandez, B.
    Herrera, R.
    Ruiz-Trejo, C.
    Brandan, M. E.
    MEDICAL PHYSICS, 2006, 854 : 42 - +
  • [35] A SCINTILLATING-FIBER HODOSCOPE USING A POSITION-SENSITIVE PHOTOMULTIPLIER
    KURODA, K
    LEHAR, F
    MAKINO, S
    MICHALOWICZ, A
    PENZO, A
    TAKEUTCHI, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (02): : 259 - 267
  • [36] POSITION-SENSITIVE DETECTOR WITH WEDGE-AND-WEDGE READOUT
    TROW, MW
    LAPINGTON, JS
    BENTLEY, RD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 344 - 347
  • [37] Readout responses of inclined strips in position-sensitive detectors
    Javanmardi, F
    Wakabayashi, G
    Minuchehr, A
    Zolfaghari, A
    Rashid, MM
    Matoba, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2321 - 2323
  • [38] TEST OF FIBER DETECTOR READOUT BY POSITION-SENSITIVE PHOTOMULTIPLIERS
    BAHR, J
    HILLER, K
    HOFFMANN, B
    LUDECKE, H
    NAHNHAUER, R
    MENCHIKOV, A
    POHL, M
    ROLOFF, HE
    VOLKERT, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 713 - 718
  • [39] MICROCHANNEL PLATES AND READOUT SYSTEMS FOR POSITION-SENSITIVE DETECTORS
    BASILIER, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 73 - 75
  • [40] FAST TRACKING DETECTOR WITH FIBER SCINTILLATORS AND A POSITION-SENSITIVE PHOTOMULTIPLIER
    SALOMON, M
    LI, V
    SMITH, G
    WU, YS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 94 - 97