Calibration of an InGaAs photodiode at 1300 nm with a cryogenic radiometer and a diode laser

被引:0
|
作者
Atkinson, E.G. [1 ]
Butler, D.J. [1 ]
机构
[1] CSIRO Natl. Measurement Laboratory, PO Box 218, Lindfield, NSW 2070, Australia
来源
Metrologia | / 35卷 / 04期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:241 / 245
相关论文
共 50 条
  • [31] Tunable diode laser absorption spectroscopy detection of N2O at 2.1 μm using antimonide laser and InGaAs photodiode
    Zhang Yong-Gang
    Zhang Xiao-Jun
    Zhu Xiang-Rong
    Li Ai-Zhen
    Liu Sheng
    CHINESE PHYSICS LETTERS, 2007, 24 (08) : 2301 - 2303
  • [32] Cryogenic laser performance of Yb:YAG diode-pumped at 940 nm and 969 nm for high power lasers
    Jambunathan, Venkatesan
    Tesnohlidkova, Lucie
    Miura, Taisuke
    Lucianetti, Antonio
    Mocek, Tomas
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,
  • [33] Prototype of Cryogenic Solar Absolute Radiometer and Transfer Radiometer for On-Board Calibration of Spectral Earth Imager
    Zajiczek, L.
    Winkler, R.
    Hobson, T.
    Green, P.
    Fox, N.
    13TH INTERNATIONAL CONFERENCE ON NEW DEVELOPMENTS AND APPLICATIONS IN OPTICAL RADIOMETRY, 2018, 972
  • [34] CALIBRATION OF A LASER DIODE SPECTROMETER
    ZASAVITSKII, II
    KOSICHKIN, YV
    KRYUKOV, PV
    NADEZHDINSKII, AI
    SHOTOV, AP
    MEASUREMENT TECHNIQUES USSR, 1982, 25 (10): : 815 - 816
  • [35] Accurate determination of the spectral responsivity of silicon trap detectors between 238 nm and 1015 nm using a laser-based cryogenic radiometer
    Werner, L
    Fischer, J
    Johannsen, U
    Hartmann, J
    METROLOGIA, 2000, 37 (04) : 279 - 284
  • [36] Temperature stability of InGaAlAs, InGaAsP, InGaAs and GaAs quantum-wells for 852 nm laser diode
    State Key Laboratory of Luminescence and Applications, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
    不详
    Faguang Xuebao, 2012, 6 (640-646):
  • [37] Efficient high power reliable InGaAs/AlGaAs (940nm) monolithic laser diode arrays
    He, X
    Ovtchinnikov, A
    Yang, S
    Harrison, J
    Feitisch, A
    ELECTRONICS LETTERS, 1999, 35 (20) : 1739 - 1740
  • [38] COMPARISON OF QUANTUM-EFFICIENT SILICON PHOTODETECTORS WITH A CRYOGENIC ABSOLUTE RADIOMETER AT A LASER WAVELENGTH OF 543,5-NM
    VARPULA, T
    LIEDQUIST, L
    LUDVIGSEN, H
    REYN, H
    DEVREEDE, J
    METROLOGIA, 1991, 28 (04) : 349 - 352
  • [39] Some quality issues of low-cost 1300nm laser diode packaged-in receptacles
    Morin, M
    Prigent, S
    Terol, G
    Devoldere, P
    FABRICATION, TESTING, AND RELIABILITY OF SEMICONDUCTOR LASERS II, 1997, 3004 : 71 - 82
  • [40] 400~900 nm spectral irradiance of cryogenic radiometer-based irradiance standard lamp using system level calibration method
    Chen H.
    Zhang L.
    Zou P.
    Xie P.
    Zheng X.
    Qiao Y.
    Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (11): : 3349 - 3353