Calibration of an InGaAs photodiode at 1300 nm with a cryogenic radiometer and a diode laser

被引:0
|
作者
Atkinson, E.G. [1 ]
Butler, D.J. [1 ]
机构
[1] CSIRO Natl. Measurement Laboratory, PO Box 218, Lindfield, NSW 2070, Australia
来源
Metrologia | / 35卷 / 04期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:241 / 245
相关论文
共 50 条
  • [1] Calibration of an InGaAs photodiode at 1300 nm with a cryogenic radiometer and a diode laser
    Atkinson, EG
    Butler, DJ
    METROLOGIA, 1998, 35 (04) : 241 - 245
  • [2] Absolute power measurements at wavelengths of 1300 nm and 1550 nm with a cryogenic radiometer and a tuneable laser diode
    Corredera, P
    Hernanz, ML
    Campos, J
    Corróns, A
    Pons, A
    Fontecha, JL
    METROLOGIA, 2000, 37 (05) : 519 - 522
  • [3] A New Spectral Responsivity Calibration Comparator of InGaAs photodiode Based on Cryogenic Radiometer Fundamental at the National Institute of Metrology of China
    He, Yingwei
    Gan, Haiyong
    Liu, Wende
    Lin, Yongjie
    Wang, Yangyang
    Xu, Ning
    Zhao, Weidiang
    Liu, Zhiwei
    Xiong, Limin
    Xu, Nan
    Lin, Yandong
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VII, 2020, 11552
  • [4] An absolute cryogenic radiometer for laser calibration and characterization of photodetectors
    Morozova, SP
    Konovodchenko, VA
    Sapritsky, VI
    Lisiansky, BE
    Morozov, PA
    Melenevsky, UA
    Petic, AG
    METROLOGIA, 1996, 32 (06) : 557 - 560
  • [5] Highly accurate optical radiation calibration of InGaAs trap based on cryogenic radiometer
    Remote Sensing Department, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
    Guangxue Jishu, 2006, SUPPL. (64-66):
  • [6] InAlGaAs-InGaAs-InP RCE PIN photodiode for 1300nm wavelength region
    Kovac, J
    Uherek, F
    Satka, A
    Waclawek, J
    Jakabovic, J
    Srnanek, R
    Rheinlander, B
    Gottschalch, V
    Hasenohrl, S
    Novak, J
    Barna, P
    Barna, A
    Wood, J
    1996 EIGHTH INTERNATIONAL CONFERENCE ON INDIUM PHOSPHIDE AND RELATED MATERIALS, 1996, : 219 - 222
  • [7] Reliability of 1300 nm laser diode for space applications.
    Pailharey, E
    Baggio, J
    D'hose, C
    Musseau, O
    PHOTONICS FOR SPACE AND RADIATION ENVIRONMENTS, 1999, 3872 : 139 - 147
  • [8] ABSOLUTE CALIBRATION OF AN ULTRAVIOLET SPECTROMETER USING A STABILIZED LASER AND A CRYOGENIC CAVITY RADIOMETER
    JAUNISKIS, L
    FOUKAL, P
    KOCHLING, H
    APPLIED OPTICS, 1992, 31 (27): : 5838 - 5843
  • [9] Calibration of radiant laser power with a cryogenic radiometer at visible wavelengths and at 10.6 μm
    Werner, G
    Liedquist, L
    OPTOELECTRONIC METROLOGY, 1998, 4018 : 73 - 78
  • [10] Calibration of absolute spectral responsivity at 1 064 nm of transfer detector against cryogenic radiometer
    Pang, Weiwei
    Zheng, Xiaobing
    Li, Jianjun
    Shi, Xueshun
    Wu, Haoyu
    Xia, Maopeng
    Gao, Dongyang
    Shi, Jianmin
    Qi, Tao
    Kang, Qing
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (12): : 3812 - 3818