DYNAMIC STUDIES OF 200 MW TURBO-GENERATOR FOUNDATION.

被引:0
|
作者
Wedpathak, A.V.
Pandit, V.K.
Bhandwalkar, P.K.
Guha, S.K.
机构
关键词
Dynamics; -; Soils;
D O I
暂无
中图分类号
学科分类号
摘要
Dynamic studies were conducted for a frame-type concrete foundation of 200 MW turbo-generator set for estimating its natural frequencies in various modes, initially by theoretical dynamic analysis, model studies and finally by prototype experiments. The results of natural frequencies obtained from these studies have been found to be in reasonably good agreement and thus ensure safe dynamic behavior of prototype foundation when subjected to actual loads.
引用
收藏
页码:181 / 186
相关论文
共 50 条
  • [1] TURBO-GENERATOR FOUNDATION DYNAMIC ANALYSIS
    Bencat, J.
    Lukac, M.
    ENGINEERING MECHANICS 2018 PROCEEDINGS, VOL 24, 2018, : 73 - 76
  • [2] Fuzzy fault diagnosis system for a 200 MW turbo-generator set
    Yang, Ping
    Wu, Jie
    Feng, Yongxin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2001, 25 (01): : 45 - 49
  • [3] Rebuilding of the seal oil system in 200MW turbo-generator
    Gui, Xiliang
    Dadianji Jishu/Large Electric Machine and Hydraulic Turbine, (06): : 51 - 56
  • [4] Fuzzy fault diagnosis system for a 200 MW turbo-generator set
    Ping, Yang
    Jie, Wu
    Yongxin, Feng
    2001, Automation of Electric Power Systems Press (25):
  • [5] Study of vibrational features of foundation of a N125MW turbo-generator
    Li, Luping
    Liu, Zeli
    Zhang, Bailin
    Zhang, Guozhong
    Xie, Penghui
    Zhou, Ke
    2000, Harbin Steam Turbine Company, China (42):
  • [6] Study on nonlinear stability for a 200 MW turbo-generator rotor-bearing system
    Cui, Ying
    Liu, Zhansheng
    Leng, Shuxiang
    Han, Wanjin
    Huang, Wenhu
    Jixie Gongcheng Xuebao, 2 (170-175):
  • [7] Dynamic Design and Simulation Analysis of 1000MW Large Turbo-Generator
    Wang Yixuan
    Wang Ying
    Qu Haifei
    Liu Xin
    2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 1650 - +
  • [8] Aging diagnosis for 300 MW turbo-generator stator insulation
    Song, Jiancheng
    Cheng, Yonghong
    Zhao, Shaoxing
    Xie, Hengkun
    Xi, Qimei
    Li, Qinghe
    Zhongguo Dianli/Electric Power, 2000, 33 (06): : 40 - 44
  • [9] Some Opinions on Type Selection of 600 MW Turbo-generator
    Mao Cuoguang
    Electricity, 2000, (01) : 31 - 37
  • [10] Identifying noise modes in estimated turbo-generator foundation models
    Friswell, MI
    Lees, AW
    Smart, MG
    Prells, U
    MODERN PRACTICE IN STRESS AND VIBRATION ANALYSIS, 1997, : 57 - 64