Low-noise analogue ICs in charge-sensitive preamplifiers

被引:0
|
作者
机构
来源
Mikroelektron | / 3卷 / 188-198期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Design of an Integrated Low-Noise Ultra-Fast Charge-Sensitive Micro-Probe for Semiconductor Detectors
    Pullia, A.
    Capra, S.
    Frontini, E.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4179 - 4183
  • [32] Design of low-noise preamplifiers for sensor applications
    Sansen, W
    NOISE IN PHYSICAL SYSTEMS AND 1/F FLUCTUATIONS, PROCEEDINGS OF THE 14TH INTERNATIONAL CONFERENCE, 1997, : 553 - 557
  • [33] Low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors
    Paulus, MJ
    Rochelle, JM
    Andreaco, MS
    Binkley, DM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1666 - 1671
  • [34] A low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors
    Paulus, MJ
    Rochelle, JM
    Andreaco, MS
    Binkley, DM
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 330 - 334
  • [35] Design and application of a charge-sensitive preamplifiers with silicon photo-diodes in TEXONO
    Zhang, Zhi-Yong
    Liu, Zheng-Shan
    Cheng, Chang
    Li, Jin
    Liu, Yan
    Shi, Feng
    Wong, Tsz-King
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2002, 22 (02):
  • [36] Integrated low-noise low-power fast charge-sensitive preamplifier for avalanche photodiodes in JFET-CMOS technology
    Pichler, BJ
    Pimpl, W
    Buttler, W
    Kotoulas, L
    Böning, G
    Rafecas, M
    Lorenz, E
    Ziegler, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2370 - 2374
  • [37] A low-noise charge-sensitive preamplifier for an X-ray detector of a Nb-based superconducting tunnel junction
    Ukibe, M
    Kishimoto, M
    Katagiri, M
    Kurakado, M
    Nakazawa, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3): : 299 - 308
  • [39] Compensation of the detector capacitance presented to charge-sensitive preamplifiers using the Miller effect
    Kwon, Inyong
    Kang, Taehoon
    Wells, Byron T.
    D'Aries, Lawrence J.
    Hammig, Mark D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 220 - 225
  • [40] LOW NOISE CHARGE-SENSITIVE PREAMPLIFIER EMPLOYING FIELD EFFECT TRANSISTORS
    PODYACHE.VN
    SHATUNOVSKII, RM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (04): : 1042 - +