Analysis of gas-liquid mass transfer in an airlift contactor with perforated plates

被引:0
|
作者
机构
[1] Krichnavaruk, Sontaya
[2] Pavasant, Prasert
来源
Pavasant, P. (prasert.p@chula.ac.th) | 1600年 / Elsevier卷 / 89期
关键词
Electric contactors - Interfaces (materials) - Mass transfer - Perforating;
D O I
暂无
中图分类号
学科分类号
摘要
This work investigated roles of an perforated plate on the gas-liquid mass transfer in an airlift contactor (ALC), and it was found that the effect of the perforated plate was twofold. Firstly, it helped in breaking up large bubbles that passed through the plate. It was observed that inserting a perforated plate could increase the interfacial area between gas and liquid to more than twice its original value. Secondly, the presence of a perforated plate seemed to lower down the mass transfer coefficient between the two phases. The analysis showed that the effect of the increase in the interfacial area between gas and liquid exceeded that of the reduction in the mass transfer coefficient. Hence, the overall rate of gas-liquid mass transfer in the employed ALC was found to be enhanced when perforated plates were inserted into the system. The effect of the configuration of perforated plate, i.e. hole size, number of hole, and the number of perforated plate, was also investigated. © 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 3
相关论文
共 50 条
  • [21] Mass Transfer in an Energy-Efficient High-Intensity Gas-Liquid Contactor
    Azizi, F.
    Al Taweel, A. M.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2015, 54 (46) : 11635 - 11652
  • [22] GAS-LIQUID MASS-TRANSFER IN ROTATING PERFORATED-DISC CONTACTORS
    YANG, WJ
    LETTERS IN HEAT AND MASS TRANSFER, 1982, 9 (02): : 119 - 129
  • [23] Gas-phase mass transfer in a centrifugal gas-liquid contactor with a stack of flexible disks as packing
    Mukherjee, R
    Deb, D
    Sandilya, P
    Rao, DP
    PROCESSING BY CENTRIFUGATION, 2001, : 51 - 60
  • [24] Mass transfer and gas-liquid circulation in an airlift bioreactor with viscous non-Newtonian fluids
    Inst.Chem.Metallurgy, Beijing 100080, China
    CHEM. ENG. J. BIOCHEM. ENG., 2 (B101-B107):
  • [25] Gas-liquid mass transfer in oil-water emulsions with an airlift bio-reactor
    Boltes, Karina
    Caro, Ainhoa
    Leton, Pedro
    Rodriguez, Antonio
    Garcia-Calvo, Eloy
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (12) : 2408 - 2412
  • [26] Study of hydrodynamics, mixing and gas-liquid mass transfer in a split-rectangular airlift reactor
    Gourich, B.
    El Azher, N.
    Vial, C.
    Soulami, M. Belhaj
    Ziyad, M.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2006, 84 (05): : 539 - 547
  • [27] Influence of impeller type on hydrodynamics and gas-liquid mass-transfer in stirred airlift bioreactor
    de Jesus, Sergio S.
    Moreira Neto, Joao
    Santana, Aline
    Maciel Filho, Rubens
    AICHE JOURNAL, 2015, 61 (10) : 3159 - 3171
  • [28] Mass transfer in gas-liquid contactors
    Gaddis, ES
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1999, 38 (4-6) : 503 - 510
  • [29] Mass transfer in gas-liquid contactors
    Gaddis, E.S.
    Chemical Engineering and Processing, 1999, 38 (4-6): : 503 - 510