EFFICIENCY OF RADON DETECTOR LR-115.

被引:0
|
作者
Ramola, R.C. [1 ]
Singh, Manwinder [1 ]
Singh, Surinder [1 ]
Virk, H.S. [1 ]
机构
[1] Guru Nanak Dev Univ, Amritsar, India, Guru Nanak Dev Univ, Amritsar, India
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
PARTICLE DETECTORS
引用
收藏
页码:235 / 236
相关论文
共 50 条
  • [21] Monitoring of the unattached fraction of radon progeny by the Kodak LR-115 Type 2, nuclear track detector
    Kvasnicka, Jiri
    Zdimal, Vladimir
    Seini, Allan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1000
  • [22] CR-39 detector compared with Kodalpha film type (LR115) in terms of radon concentration
    Dwaikat, Nidal
    Safarini, Ghassan
    El-hasan, Mousa
    Iida, Toshiyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02): : 289 - 291
  • [23] A semi-empirical approach to estimate the parameters determining the LR-115 detector response in radon measurements
    Rojas, Jhonny
    Palacios, Daniel
    Pereyra, Patrizia
    Perez, Bertin
    Sajo Bohus, Laszlo
    Elena Lopez, Maria
    RADIATION MEASUREMENTS, 2018, 118 : 36 - 42
  • [24] Sensitivity of LR 115 detectors in hemispherical chambers for radon measurements
    Nikezic, D
    Ng, FMF
    Yu, KN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 217 (04): : 637 - 643
  • [25] THE EFFICIENCY AND ANGULAR SENSITIVITY OF THE LR-115 NUCLEAR TRACK DETECTOR TO ALPHA-PARTICLES
    PLANINIC, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 71 (01): : 95 - 98
  • [26] CALIBRATION COEFFICIENT FOR RADON MEASUREMENTS WITH LR-115-II TRACK DETECTOR IN DIFFERENT TYPES OF DIFFUSION-CHAMBERS
    NIKEZIC, D
    VELICKOVIC, D
    RADIATION MEASUREMENTS, 1994, 23 (01) : 219 - 223
  • [27] Further studies on sensitivity of a LR-115 based radon dosemeter
    Bagnoli, F
    Bochicchio, F
    Bucci, S
    Marocco, D
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 207 - 210
  • [28] Effects of stirring on the bulk etch rate of LR 115 detector
    Yip, CWY
    Ho, JPY
    Koo, VSY
    Nikezic, D
    Yu, KN
    RADIATION MEASUREMENTS, 2003, 37 (03) : 197 - 200
  • [29] Use of LR-115 detector to measure radon concentrations in milk and tea samples collected from misan markets in Iraq
    Hussein A.M.A.
    Shinen M.H.
    Aswood M.S.
    Iranian Journal of Medical Physics, 2019, 16 (05) : 319 - 322
  • [30] THE MEASUREMENT OF RADON EMANATION RATES FROM SOME ROCK SPECIMENS AND BUILDING-MATERIALS USING RADON EMANOMETRY AND LR-115 PLASTIC TRACK DETECTOR
    SINGH, S
    GHUMAN, HS
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 621 - 624