SOFT X-RAY DETECTION WITH CHARGE COUPLED DEVICES.

被引:0
|
作者
Lowrance, John L.
Renda, George
机构
来源
| 1976年
关键词
PLASMAS - Measurements - Semiconductor devices; Charge coupled - X-rays;
D O I
暂无
中图分类号
学科分类号
摘要
In nuclear fusion research it is important to measure the impurities in the plasma and the total energy being radiated. The sensitivity of silicon over a broad spectral range makes it very attractive and when configured as a CCD it is even more attractive because of its relative insensitivity to strong magnetic fields associated with plasma containment. The Fairchild 201-CCD has been illuminated with X-rays from a copper target to explore its applicability for X-ray imagery. The Reticon 512 B/24 self-scanned linear array has been evaluated using copper, aluminum and carbon targets.
引用
收藏
页码:83 / 85
相关论文
共 50 条
  • [1] Measurement of X-ray polarisation with small pixel charge coupled devices.
    Hill, JE
    Holland, AD
    Castelli, CM
    Short, ADT
    Turner, MJL
    Burt, D
    [J]. EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 241 - 249
  • [2] X-RAY IMAGING WITH CHARGE-COUPLED-DEVICES
    PECKERAR, MC
    BAKER, WD
    NAGEL, DJ
    BLEACH, RD
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (04): : 597 - 597
  • [3] Modelling the x-ray response of charge coupled devices
    [J]. Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 362 (2-3):
  • [4] SOFT-X-RAY RESPONSE OF CHARGE-COUPLED-DEVICES
    CASTELLI, C
    WELLS, A
    MCCARTHY, K
    HOLLAND, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 240 - 243
  • [5] MODELING THE X-RAY RESPONSE OF CHARGE-COUPLED-DEVICES
    MCCARTHY, KJ
    OWENS, A
    HOLLAND, AD
    WELLS, AA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 362 (2-3): : 538 - 546
  • [6] Detection of x-ray polarization with a charge coupled device
    Tusnemi, H.
    Hayashida, K.
    Tamura, K.
    Nomoto, S.
    Wada, M.
    Hirano, A.
    Miyata, E.
    [J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, A321 (03) : 629 - 631
  • [7] X-RAY RADIATION EFFECTS ON SEMICONDUCTOR DEVICES.
    Chauhan, A.S.
    Maheshwari, L.K.
    [J]. Indian Journal of Pure and Applied Physics, 1975, 13 (04): : 226 - 228
  • [8] CHARGE-COUPLED DEVICES.
    Mavor, John
    [J]. Engineering (London), 1978, 218 (01):
  • [9] Calibration of charge coupled devices and a pinhole transmission grating to be used as elements of a soft x-ray spectrograph
    Schriever, G
    Lebert, R
    Naweed, A
    Mager, S
    Neff, W
    Kraft, S
    Scholze, F
    Ulm, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (09): : 3301 - 3306
  • [10] APPLICATIONS OF CHARGE-COUPLED-DEVICES TO X-RAY ASTROPHYSICS MISSIONS
    LUMB, DH