PHASE-TO-PHASE SWITCHING SURGE DESIGN.

被引:0
|
作者
Anon
机构
关键词
ELECTRIC LINES - Surges - FLASHOVER;
D O I
暂无
中图分类号
学科分类号
摘要
Phase-phase switching surge design information has been obtained from a project, the purpose of which was to develop methods for the design of 115-138 kv compact transmission lines, but the results are applicable to all designs with spacings in the range tested. Advanced statistical methods were used. Switching surge flashover measurements were made for phase-phase spacings of 3, 6, and 12 feet, on line lengths of 30, 150 and 1200 feet. Effects of the surge ratio alpha, the surge voltage on the third phase, line hardware, and height were studied. Weather correction factors were obtained from the test results as concomitant variables. Methods developed offer capabilities for statistical analysis of large complex data sets. The techniques permit rapid initial approximations, followed by sophisticated analyses permitting Gaussian or extremal function behavior for the data. The techniques include procedures for automatic rejection of spurious readings, and for 'censored' analyses which utilize flashover voltage information in addition to the binary flashover/no flashover records. Results are presented in a simplified form for ready use by design engineers, and can be used with a complementary TNA-generated system performance data base prepared in an associated EPRI project RP260-2, 115-138 kv Bundled Circuit Design. The combination permits probabilistic designs using simple procedures.
引用
收藏
相关论文
共 50 条
  • [31] The competence and expertise of architects during the phase of design.
    Raynaud, D
    SOCIOLOGIE DU TRAVAIL, 2001, 43 (04) : 451 - 469
  • [32] LIMITATION OF PHASE-TO-PHASE AND PHASE-TO-GROUND SWITCHING SURGES. FIELD TESTS IN BONNEVILLE POWER ADMINISTRATION 550 kV SYSTEM.
    Legate, A.C.
    Stemler, G.E.
    Reichert, K.
    Cuk, N.P.
    1600, CIGRE, Paris, Fr
  • [33] Motion characteristics of a tubular linear switched reluctance actuator (T-LSRA) using phase-to-phase switching algorithm
    Yeo, Chin Kiat
    Ghazaly, Mariam Md
    Tee, Siau Ping
    Nadzmy, Fawwaz
    Chong, Shin Horng
    Abdullah, Zulkeflee
    PROCEEDINGS OF MECHANICAL ENGINEERING RESEARCH DAY 2019 (MERD'19), 2019, : 294 - 296
  • [34] Phase-to-phase distance relay based on the measured impedance trajectory
    Liu, Huanzhang
    Liu, Qiankuan
    Huang, Shaofeng
    Yang, Qixun
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 675 - +
  • [35] Influence of load current on healthy phase-to-phase distance relay
    Li, Bin
    Fan, Ruiqing
    Yu, Xuan
    He, Jiali
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (28): : 66 - 71
  • [36] Phase-to-phase perovskite growth transformation in thin PZT films
    I. P. Pronin
    E. Yu. Kaptelov
    S. V. Senkevich
    T. A. Shaplygina
    V. A. Klimov
    V. P. Pronin
    Bulletin of the Russian Academy of Sciences: Physics, 2010, 74 (9) : 1304 - 1306
  • [37] TAKE THE GUESSWORK OUT OF PHASE LOCKED LOOP DESIGN.
    Kesner, Don
    EDN, 1973, 18 (01) : 54 - 60
  • [38] Penetration level calculation with considerations of phase-to-phase short circuit fault
    Zhejiang University, Hangzhou 310027, China
    不详
    不详
    Dianli Xitong Zidonghue, 2008, 3 (82-86): : 82 - 86
  • [39] Unbalanced phase-to-phase voltage compensators applied to radial distribution feeders
    Pires, RC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 806 - 812
  • [40] Estimation of Phase-to-Phase Flashover Rate of 6.6 kV Distribution Lines
    Ishimoto, Kazuyuki
    Mori, Ryota
    Asakawa, Akira
    Hara, Shingo
    Arai, And Nobutaka
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,