ELECTRONICS FOR A XENON TIME PROJECTION CHAMBER.

被引:0
|
作者
Iqbal, M.Z. [1 ]
O'Callaghan, B.M.G. [1 ]
Wong, H.T.-K. [1 ]
机构
[1] California Inst of Technology,, Pasadena, CA, USA, California Inst of Technology, Pasadena, CA, USA
来源
关键词
AMPLIFIERS - DATA PROCESSING - Data Acquisition - ELECTRONIC CIRCUITS;
D O I
暂无
中图分类号
学科分类号
摘要
The design and construction of the electronics for a 336-channel xenon time projection chamber is discussed. Electron trajectories, with charge blobs at the end due to high charge deposition, are reconstructed using a two-level discriminator system. The trajectory information is stored in a memory bank which was designed compatible with the CAMAC standard, for ease of data transfer to a main frame computer. With a sampling rate of 8 MHz, the electronics can process 5 events per second.
引用
收藏
页码:387 / 391
相关论文
共 50 条
  • [31] TIME PROJECTION CHAMBER
    MARX, JN
    NYGREN, DR
    PHYSICS TODAY, 1978, 31 (10) : 46 - 53
  • [32] Breakup, transfer, and fusion studies of exotic "halo" nuclei using an active-target time projection chamber.
    Kolata, J. J.
    Bazin, Daniel
    Suzuki, Daisuke
    Mittig, Wolfgang
    5TH INTERNATIONAL CONFERENCE FUSION11, 2011, 17
  • [33] FILMLESS METHOD OF CONTROLLING THE MEMORY TIME OF A STREAMER CHAMBER.
    Volodin, V.D.
    Glagoleva, N.S.
    Matyushin, A.T.
    Matyushin, V.T.
    Musul'manbekov, Zh.Zh.
    Nurgozhin, N.N.
    1978, 21 (4 pt 1): : 890 - 892
  • [34] A liquid xenon time projection chamber for γ-ray imaging in astrophysics:: present status and future directions
    Aprile, E
    Curioni, A
    Egorova, V
    Giboni, KL
    Oberlack, U
    Ventura, S
    Doke, T
    Takizawa, K
    Chupp, EL
    Dunphy, PP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3): : 256 - 261
  • [35] Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage
    Stiegler, T.
    Sangiorgio, S.
    Brodsky, J. P.
    Heffner, M.
    Al Kharusi, S.
    Anton, G.
    Arnquist, I. J.
    Badhrees, I
    Barbeau, P. S.
    Beck, D.
    Belov, V
    Bhatta, T.
    Bolotnikov, A.
    Breur, P. A.
    Brown, E.
    Brunner, T.
    Caden, E.
    Cao, G. F.
    Cao, L.
    Chambers, C.
    Chana, B.
    Charlebois, S. A.
    Chiu, M.
    Cleveland, B.
    Coon, M.
    Craycraft, A.
    Dalmasson, J.
    Daniels, T.
    Darroch, L.
    De St Croix, A.
    Der Mesrobian-Kabakian, A.
    Deslandes, K.
    DeVoe, R.
    Di Vacri, M. L.
    Dilling, J.
    Ding, Y. Y.
    Dolinski, M. J.
    Dragone, A.
    Echevers, J.
    Edaltafar, F.
    Elbeltagi, M.
    Fabris, L.
    Fairbank, D.
    Fairbank, W.
    Farine, J.
    Ferrara, S.
    Feyzbakhsh, S.
    Gallina, G.
    Gautam, P.
    Giacomini, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1000
  • [36] Calibration of a two-phase xenon time projection chamber with a 37Ar source
    Boulton, E. M.
    Bernard, E.
    Destefano, N.
    Edwards, B. N. V.
    Gai, M.
    Hertel, S. A.
    Horn, M.
    Larsen, N. A.
    Tennyson, B. P.
    Wahl, C.
    McKinsey, D. N.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [37] OPERATING EXPERIENCE WITH THE MARK J TIME EXPANSION CHAMBER.
    Anderhub, H.
    Anders, H.
    Ansari, S.
    Boehm, A.
    Bourquin, M.
    Bucher, A.
    Burger, J.
    Chen, M.
    Commichau, V.
    Deutschmann, M.
    Dhina, M.
    Fehlmann, J.
    Nuclear instruments and methods in physics research, 1987, A265 (1-2): : 50 - 59
  • [38] Calorimetric respiratory chamber.
    Letulle
    Pompilian
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1906, 143 : 932 - 933
  • [39] INDUCTION DRIFT CHAMBER.
    Roderburg, E.
    Baecker, A.
    Krieger, H.
    Mattern, D.
    Walenta, A.H.
    Zech, G.
    Nuclear instruments and methods in physics research, 1986, A252 (2-3): : 285 - 291
  • [40] About the Geiger chamber.
    Wulf, T
    PHYSIKALISCHE ZEITSCHRIFT, 1925, 26 : 382 - 391