LOAD FOLLOW OPERATION IN ELECTRICITE DE FRANCE POWER PLANTS AND FUEL BEHAVIOUR EVALUATION.

被引:0
|
作者
Gautier, B. [1 ]
Stora, J.P. [1 ]
机构
[1] Electricite de France, Paris, Fr, Electricite de France, Paris, Fr
关键词
FAILURE ANALYSIS - NUCLEAR POWER PLANTS - STRESSES - Analysis - ZIRCONIUM AND ALLOYS - Deformation;
D O I
暂无
中图分类号
学科分类号
摘要
Power changes, totally or partly made by control rod movements, lead to important variations in the axial profile and therefore in the local fuel power. Due to differential thermal expansion, the uranium dioxide strains the cladding and the resulting stresses increase the risk of PCI failure. Some studies on fuel rod behaviour under load follow duty have been performed to evaluate such a risk. These studies consist of the calculation of the stress evolution, according to the power and the velocity of the load variation, and also the calculation of the associated stress relaxation and therefore the cladding deformation. The results are compared with the ramp test data and, based on these tests, the PCI failure criterion is defined as the ratio of the maximum stress in the cladding to the zircaloy yield point in the temperature and irradiation conditions at which interaction occurs. The results of the calculation for the more constrained conditions under load follow duty show that the risk of fuel failure is almost zero. In addition, the contribution to the fatigue behaviour of the cladding is less than 10%, all the other design criteria being satisfied, of course.
引用
收藏
页码:285 / 296
相关论文
共 50 条
  • [21] RESULTS OF TESTS AND EXPERIENCE OF ELECTRICITE-DE-FRANCE REGARDING MATERIALS WORKING AT HIGH-TEMPERATURE IN THE CONVENTIONAL THERMAL POWER-PLANTS
    PONCIN, P
    MOUSSET, P
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 1981, 6 (03): : 225 - 236
  • [22] LOAD FOLLOWING OPERATION OF NUCLEAR-POWER-PLANTS
    WAKABAYASHI, J
    MORI, T
    SUMIDA, S
    ISHII, K
    KAWATA, N
    IIJIMA, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1986, 28 (10): : 913 - 923
  • [23] Supervision Carried Out by the Electricite de France (E. D. F. ) During the Construction of Nuclear Power Plants.
    Vaujour, Jean Alain
    Bonnard, Yvon
    Annales des Mines, 1974, : 41 - 46
  • [24] Epidemiological surveillance at Electricite de France-Gaz de France:: health assessment of nuclear power plant employees between 1993 and 1998
    Gros, H
    Chevalier, A
    Carrié, E
    Lahon, G
    OCCUPATIONAL MEDICINE-OXFORD, 2002, 52 (01): : 35 - 44
  • [25] NON-PROGRAMMED PASSAGES TO NIL LOAD OF THERMAL BLOCKS AT ELECTRICITE-DE-FRANCE, THEIR FREQUENCY AND THEIR CAUSES
    JUBLANC, P
    REVUE GENERALE DE THERMIQUE, 1975, 14 (158): : 107 - 114
  • [26] Nuclear power plants simulators at Electricity de France
    Ponthieu, L
    Iffenecker, F
    Pentori, B
    Crehange, G
    Langlois, R
    ESM'99 - MODELLING AND SIMULATION: A TOOL FOR THE NEXT MILLENNIUM, VOL II, 1999, : 513 - 516
  • [27] FUEL ASSEMBLY VERIFICATION FOR SAFE OPERATION OF NUCLEAR POWER PLANTS
    Rajput, Hitesh
    Som, Tanmoy
    Kar, Soumitra
    NUCLEAR TECHNOLOGY, 2015, 192 (02) : 125 - 132
  • [28] The Load Follow Capability of Nuclear Power plants - Experience and Outlook
    Timpf, Wolfgang
    Fuchs, Michael
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2012, 57 (05): : 313 - 316
  • [29] New Advances in the Planning of the National Grid at the Electricite de France: Taking Fuel Costs Savings and Uncertainty into Account.
    Meslier, F.
    Faugeras, J.F.
    Bulletin de la Direction des etudes et recherches. Serie B, Reseaux electriques, materiels electriques, 1984, (02): : 5 - 11
  • [30] Experience with the Seconary Water Chemistry in the Pressurized Water Reactor Nuclear Power Stations of Electricite de France (EdF).
    Berge, Ph.
    Fiquet, J.M.
    VGB-Kraftwerkstechnik, 1986, 66 (11): : 1072 - 1076