The effects of electrical system and station faults on the magnitude and characteristics of torques in the turbine and generator shafts are investigated and compared. The study is mainly focused on the influences of turboset design, oscillatory system as well as system and operating conditions on the torques arising during automatic clearing of three-phase system faults close to the station with recovery of system voltage. On the basis of the results obtained proposals are made for planning system protection and for the future turboset design.
引用
收藏
页码:164 / 171
相关论文