Analysis and assessment of errors in a parallel data acquisition system for electrical impedance tomography

被引:18
|
作者
Rosell, J. [1 ]
Murphy, D. [1 ]
Pallas, R. [1 ]
Rolfe, P. [1 ]
机构
[1] Division de Instrumentacion y Bioingerieria, ETSI Telecomunicacion, 08080 Barcelona, Spain
来源
关键词
Computer Systems; Digital--Parallel Processing - Data Processing--Data Acquisition - Electronic Circuits--Design;
D O I
10.1088/0143-0815/9/4A/016
中图分类号
学科分类号
摘要
Three possible data collection configurations for electrical impedance tomography are considered. These are serial current, intermediate parallel and fully parallel operations. Measurement errors due to stray capacitances, common-mode signals and contact impedance are considered. It is concluded that a parallel system offers advantages in terms of either speed or signal-to-noise ratio but may give larger common-mode errors.
引用
收藏
页码:93 / 99
相关论文
共 50 条
  • [21] A Parallel Impedance Measurement System for Electrical Impedance Tomography System with Multi-Microcontroller-Unit Architecture
    Deng, Qilong
    Su, Yang
    Hu, Siyi
    Xiong, Xiaodong
    Juan, Ruoyu
    Zhang, Yan
    Ma, Hanbin
    2018 IEEE INTERNATIONAL CONFERENCE ON MANIPULATION, MANUFACTURING AND MEASUREMENT ON THE NANOSCALE (3M-NANO) - CONFERENCE PROCEEDINGS, 2018, : 397 - 401
  • [22] A electrical impedance tomography system
    Peng, Y
    Mo, YL
    IEEE EMBS APBME 2003, 2003, : 280 - 281
  • [23] The study on image data acquisition system for electrical capacitance tomography system
    Li, Yan
    Jin, Tianbo
    Meng, Xiaoying
    Chen, Deyun
    Zhang, Liyong
    ICIEA 2007: 2ND IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-4, PROCEEDINGS, 2007, : 1635 - 1638
  • [24] Development of a portable electrical impedance tomography data acquisition system for near-real-time spatial sensing
    Huang, Shieh-Kung
    Loh, Kenneth J.
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2015, 2015, 9435
  • [25] Data acquisition system for impedance tomography for measuring the distribution of moisture in walls
    Biernat, Katarzyna
    Filipowicz, Stefan F.
    Nita, Konrad
    Sikora, Jan
    Wojtowicz, Stefan
    9TH INTERNATIONAL CONFERENCE: MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, VOLS 1-3, 2008, : 231 - 234
  • [26] Design and implementation of data acquisition system for the electrical capacitance tomography
    Chen, De-Yun
    Gao, Ming
    Li, Wei
    Wang, Li-Li
    Wang, Fei-Hu
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2013, 17 (05): : 87 - 92
  • [27] Optimization design of electrical resistance tomography data acquisition system
    Dong, Feng
    Li, Er-Ping
    Wang, Bin-Bin
    PROCEEDINGS OF 2007 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2007, : 1454 - 1458
  • [28] Series reversion for electrical impedance tomography with modeling errors *
    Garde, H.
    Hyvonen, N.
    Kuutela, T.
    INVERSE PROBLEMS, 2023, 39 (08)
  • [29] Approach to Compensate Measurement Errors in Electrical Impedance Tomography
    Menden, Tobias
    Orschulik, Jakob
    Tholen, Toni
    Leonhardt, Steffen
    Walter, Marian
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [30] Sweep data of electrical impedance tomography
    Hakula, Harri
    Harhanen, Lauri
    Hyvonen, Nuutti
    INVERSE PROBLEMS, 2011, 27 (11)