Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase

被引:0
|
作者
Cheon, G.-J. [1 ]
Chandran, K.B. [1 ]
机构
[1] Department of Mechanical Engineering, Won-Kwang University, Iri City, Jeon-Buk 570-749, Korea, Republic of
关键词
Bubbles (in fluids) - Cavitation - Computational methods - Continuum mechanics - Equations of motion - Flow measurement - Fluid dynamics - Gravitation - Loads (forces) - Mathematical models - Stress analysis - Unsteady flow;
D O I
暂无
中图分类号
学科分类号
摘要
An analysis of the dynamics in the closing phase of the occluder of a mechanical monoleaflet heart valve prosthesis is presented. The dynamic analysis of the fluid in the vicinity of the occluder was based on the control volume approach. The backflow velocity of the fluid was computed by applying the continuity and momentum equations in the unsteady state.
引用
收藏
页码:452 / 459
相关论文
共 50 条
  • [31] ALLOPLASTIC CARDIAC-VALVE PROSTHESIS - SOUND ANALYSIS OF OPENING AND CLOSING
    MEYER, W
    HERZ KREISLAUF, 1974, 6 (11): : 600 - 606
  • [32] Mechanical heart valve prosthesis and warfarin - Treatment quality and prognosis
    Grzymala-Lubanski, Bartosz
    Labaf, Ashkan
    Englund, Erling
    Svensson, Peter J.
    Sjalander, Anders
    THROMBOSIS RESEARCH, 2014, 133 (05) : 795 - 798
  • [33] Sarcoma associated with silver coated mechanical heart valve prosthesis
    Grubitzsch, H
    Wollert, HG
    Eckel, L
    ANNALS OF THORACIC SURGERY, 2001, 72 (05): : 1739 - 1740
  • [34] Thrombosed mechanical heart valve prosthesis in the mitral position -: Reply
    Chaudhuri, N
    ANNALS OF THORACIC SURGERY, 2000, 70 (04): : 1449 - 1449
  • [35] Stereo particle image velocimetry on mechanical heart valve prosthesis
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 922 - 922
  • [36] Use of enoxaparin in a pregnant woman with a mechanical heart valve prosthesis
    Ellison, J
    Thomson, AJ
    Walker, ID
    Greer, IA
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2001, 108 (07): : 757 - 759
  • [37] Current Echocardiography: Heart Failure with mechanical Aortic Valve Prosthesis
    Glaser, F.
    JOURNAL FUR KARDIOLOGIE, 2007, 14 (9-10): : 292 - 296
  • [38] CFD simulation of a novel bileaflet mechanical heart valve prosthesis
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 868 - 868
  • [40] Mechanical heart valve prosthesis without Marcumar: The long search
    Sievers H.-H.