Use of a fibre-based light sensor for the calibration of scanning probe microscopy piezos

被引:0
|
作者
Sturm, H. [1 ]
Heyde, M. [2 ]
Rademann, K. [2 ]
机构
[1] Fed. Institue of Mat. Research (BAM), Lab. Vl.32, D-12200 Berlin, Germany
[2] Institute of Physical Chemistry, Humboldt University, Bunsenstr. 1, D-10117 Berlin, Germany
来源
关键词
Calibration - Crystallography - Hysteresis - Interferometry - Piezoelectric devices - Probes - Scanning tunneling microscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Scanners for Scanning Probe Microscopes (SPM) are generally built of piezos, which are used to move the sample with respect to the tip in x-, y- or z-direction or vice versa. These piezoelectric scanners are usually calibrated by the manufacturer with laser interferometry, with a calibration grid or with the crystallographic or artificial step of a known height standard. However, the displacement depends on the voltage history of the piezoelectric device. In order to avoid this effect for the x- and y-positions, SPM data are generally collected in one lateral direction to minimize the divergence between commanded position and true position. The aim of this work is to present the usefulness of a cheap and easy-to-use fibre optic displacement sensor. The sensor can be used to measure static and dynamic displacement of a z-piezo in order to find a calibration procedure or at least an error look-up table for open-loop systems. The collected data of two different piezo scanner types can be used to characterize their nonlinearity and hysteresis.
引用
收藏
页码:225 / 234
相关论文
共 50 条
  • [31] Calibration and examination of piezoresistive Wheatstone bridge cantilevers for scanning probe microscopy
    Gotszalk, T
    Grabiec, P
    Rangelow, IW
    ULTRAMICROSCOPY, 2003, 97 (1-4) : 385 - 389
  • [32] Thermal probe self-calibration in ac scanning thermal microscopy
    Chirtoc, M
    Filip, X
    Henry, JF
    Antoniow, JS
    Chirtoc, I
    Dietzel, D
    Meckenstock, R
    Pelzl, J
    SUPERLATTICES AND MICROSTRUCTURES, 2004, 35 (3-6) : 305 - 314
  • [33] An electret microphone as a force sensor for combined scanning probe microscopy
    Schenk, M
    Amrein, M
    Reichelt, R
    ULTRAMICROSCOPY, 1996, 65 (1-2) : 109 - 118
  • [34] Photonic Crystal Fibre-Based Plasmon Sensor for Glucose Level Detection in Urine
    Das, Sandip
    Sen, Riya
    PLASMONICS, 2024, 19 (01) : 65 - 74
  • [35] Performances of different metals in optical fibre-based surface plasmon resonance sensor
    Sharma, Navneet K.
    PRAMANA-JOURNAL OF PHYSICS, 2012, 78 (03): : 417 - 427
  • [36] Optimal refractive index design for an optical fibre-based evanescent field sensor
    Dower, Peter M.
    Farrell, Peter M.
    Gibson, Brant C.
    SYSTEMS & CONTROL LETTERS, 2007, 56 (9-10) : 634 - 645
  • [37] Microstructured polymeric cantilevers for use in scanning probe microscopy
    Stürmer, H
    Köhler, JM
    Jovin, TM
    PRECISION ENGINEERING, NANOTECHNOLOGY, VOL. 2, 1999, : 251 - 251
  • [38] Formation and use of positioning marks in scanning probe microscopy
    V. N. Lozovskii
    S. N. Chebotarev
    V. A. Irkha
    G. V. Valov
    Technical Physics Letters, 2010, 36 : 737 - 738
  • [39] Formation and use of positioning marks in scanning probe microscopy
    Lozovskii, V. N.
    Chebotarev, S. N.
    Irkha, V. A.
    Valov, G. V.
    TECHNICAL PHYSICS LETTERS, 2010, 36 (08) : 737 - 738
  • [40] The use of scanning probe microscopy in surface finishing and engineering
    Smith, JR
    Campbell, SA
    Walsh, FC
    TRANSACTIONS OF THE INSTITUTE OF METAL FINISHING, 1998, 76 : 53 - 61