Total Pu measurement in material with passive coincidence neutron count

被引:0
|
作者
Wang, Xiaozhong [1 ]
Jia, Xiangjun [1 ]
Liu, Jiangang [1 ]
Tan, Yajun [1 ]
Zhang, Wenliang [1 ]
Li, Ze [1 ]
机构
[1] China Inst of Atomic Energy, Beijing, China
关键词
Measurements - Neutron detectors - Nondestructive examination - Nuclear fuels;
D O I
暂无
中图分类号
学科分类号
摘要
The measurement technique for some plutonium-bearing materials was described. The coincidence count on the spontaneous neutron of even-mass Pu isotope was measured with a high level neutron coincidence counter. The total Pu in material was calculated out in term of the effective 240Pu isotope composition. The plutonium in some materials (such as oxide, powder, waste, alloy, etc.) of one facility have been measured. Some of uncertain ties in measurement were discussed. The uncertainty of Pu isotope composition is one of main uncertainty and the total uncertainty of the data is mostly between 8%-11%. The most of data are consistent in 10% with declared value.
引用
收藏
页码:233 / 238
相关论文
共 50 条
  • [1] Research on Correction Method for Uranium Interference in Passive Neutron Coincidence Counting Method for Pu Measurement in MOX Fuel
    Zhang, Yuqi
    Xu, Xiaoming
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2024, 58 (06): : 1372 - 1379
  • [2] 240Pu effective mass of 238Pu and 242Pu in relation to passive neutron coincidence and multiplicity counting
    Croft, S.
    Bourva, L.C.-A.
    Weaver, D.R.
    Ottmar, H.
    JNMM, Journal of the Institute of Nuclear Materials Management, 2001, 30 (01): : 10 - 19
  • [3] CALIBRATION OF NEUTRON COINCIDENCE INSTRUMENTS FOR PU DETERMINATION
    KOSITSYN, VF
    KONYAEV, AE
    SOVIET RADIOCHEMISTRY, 1990, 32 (05): : 554 - 559
  • [4] Passive neutron multiplicity device for 240Pu measurement based on FPGA
    Zhang, Yan
    Zhang, Hao-Ran
    Wang, Ren-Bo
    Li, Ming-Yu
    Chen, Rui
    Wang, Hai-Tao
    Meng, Xiang-Ting
    Zhou, Shu-Min
    Tang, Bin
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (09)
  • [5] COINCIDENCE MEASUREMENT OF NEUTRON ENERGY
    WORTH, DC
    PHYSICAL REVIEW, 1949, 75 (05): : 903 - 903
  • [6] RAPID TOTAL NUCLEATED CELL COUNT MEASUREMENT OF LEUKAPHERESIS MATERIAL
    Byrne, J.
    Chen, A.
    Velickovic, Z.
    Rasko, J.
    CYTOTHERAPY, 2021, 23 (05) : S197 - S197
  • [7] COINCIDENCE MEASUREMENT OF NEUTRON ENERGIES
    WORTH, DC
    PHYSICAL REVIEW, 1949, 75 (08): : 1303 - 1303
  • [8] Determining Pu isotopic composition and Pu content of PuBe sources by neutron coincidence technique
    Nguyen, Cong Tam
    Bagi, Janos
    Lakosi, Laszlo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 262 (01): : 75 - 80
  • [9] Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting
    Bourva, LCA
    Croft, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (03): : 485 - 508
  • [10] INVIVO MEASUREMENT OF TOTAL-BODY CARBON USING PU-238/BE NEUTRON SOURCES
    SUTCLIFFE, JF
    MITRA, S
    HILL, GL
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (08): : 1089 - 1098