Ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane

被引:1
|
作者
Sakakida, Michiharu [1 ]
Nishida, Kenro [1 ]
Shichiri, Motoaki [1 ]
Ishihara, Kazuhiko [1 ]
Nakabayashi, Nobuo [1 ]
机构
[1] Kumamoto Univ Medical Sch, Kumamoto, Japan
关键词
Artificial organs - Biocompatibility - Calibration - Derivatives - Grafting (chemical) - Iron compounds - Morphology - Organometallics - Plastic coatings - Polymeric membranes - Service life - Stability;
D O I
暂无
中图分类号
学科分类号
摘要
A ferrocene-mediated needle-type glucose sensor covered with a newly designed biocompatible membrane of 2-methacryloyloxyethyl phosphorylcholine (MPC) has been developed and its characteristics examined in vitro and in vivo. Application of ferrocene derivatives to the glucose sensor could solve the oxygen-limitation problems, and also compensate the sensor decay due to an insufficient microconvection and diffusion of oxygen resulting from protein fixation on the sensor surface during continuous subcutaneous tissue glucose monitoring. The MPC membrane, a hydrophobic polymer surface covered with a grafted hydrophilic phosphorylcholine chain, has the potential for suppressing adsorption of biochemical molecules due to the mobility of the grafted polymer chain. With this glucose sensor covered with an MPC membrane, subcutaneous tissue glucose concentrations can be monitored for up to seven days without any in situ calibrations, followed by 14 days with one-point in situ calibrations. Therefore, we conclude that a ferrocene-mediated needle-type glucose sensor covered with an MPC membrane is stable and reliable, as compared to any other glucose sensors already developed, and can thus be applied for continuous glucose monitoring and for glycaemic control with a wearable artificial endocrine pancreas.
引用
收藏
页码:319 / 322
相关论文
共 37 条
  • [1] FERROCENE-MEDIATED NEEDLE-TYPE GLUCOSE SENSOR COVERED WITH NEWLY DESIGNED BIOCOMPATIBLE MEMBRANE
    SAKAKIDA, M
    NISHIDA, K
    SHICHIRI, M
    ISHIHARA, K
    NAKABAYASHI, N
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 319 - 322
  • [2] DEVELOPMENT OF A FERROCENE-MEDIATED NEEDLE-TYPE GLUCOSE SENSOR COVERED WITH NEWLY DESIGNED BIOCOMPATIBLE MEMBRANE, 2-METHACRYLOYLOXYETHYL PHOSPHORYLCHOLINE-CO-N-BUTYL METHACRYLATE
    NISHIDA, K
    SAKAKIDA, M
    ICHINOSE, K
    UEMURA, T
    UEHARA, M
    KAJIWARA, K
    MIYATA, T
    SHICHIRI, M
    ISHIHARA, K
    NAKABAYASHI, N
    [J]. MEDICAL PROGRESS THROUGH TECHNOLOGY, 1995, 21 (02) : 91 - 103
  • [3] DEVELOPMENT OF A FERROCENE-MEDIATED NEEDLE-TYPE GLUCOSE SENSOR COVERED WITH NEWLY DESIGNED BIOCOMPATIBLE MEMBRANE, 2-METHACRYLOYLOXYETHYL PHOSPHORYLCHOLINE-CO-N-BUTYL METHACRYLATE
    NISHIDA, K
    SAKAKIDA, M
    ICHINOSE, K
    SHOMIDA, S
    UEMURA, T
    UEHARA, M
    KAJIWARA, KI
    MIYATA, T
    SHICHIERI, M
    ISHIHARA, K
    NAKABAYASHI, N
    [J]. DIABETES, 1995, 44 : A127 - A127
  • [4] BIOCOMPATIBLE NEEDLE-TYPE GLUCOSE SENSOR WITH POTENTIAL FOR USE IN-VIVO
    CHEN, CY
    SU, YC
    ISHIHARA, K
    NAKABAYASHI, N
    TAMIYA, E
    KARUBE, I
    [J]. ELECTROANALYSIS, 1993, 5 (04) : 269 - 276
  • [5] NEEDLE-TYPE GLUCOSE SENSOR
    SHICHIRI, M
    KAWAMORI, R
    YAMASAKI, Y
    [J]. METHODS IN ENZYMOLOGY, 1988, 137 : 326 - 334
  • [6] SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS
    CLAREMONT, DJ
    SAMBROOK, IE
    PENTON, C
    PICKUP, JC
    [J]. DIABETOLOGIA, 1986, 29 (11) : 817 - 821
  • [7] POTENTIALLY-IMPLANTABLE, FERROCENE-MEDIATED GLUCOSE SENSOR
    CLAREMONT, DJ
    PENTON, C
    PICKUP, JC
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (03): : 272 - 274
  • [8] A BIOCOMPATIBLE NEEDLE-TYPE GLUCOSE SENSOR BASED ON PLATINUM-ELECTROPLATED CARBON ELECTRODE
    CHEN, CY
    TAMIYA, E
    ISHIHARA, K
    KOSUGI, Y
    SU, YC
    NAKABAYASHI, N
    KARUBE, I
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 36 (03) : 211 - 226
  • [9] INVIVO EVALUATION OF A GLUCOSE SENSOR WITH FERROCENE-MEDIATED ELECTRON-TRANSFER
    CLAREMONT, DJ
    SAMBROOK, IE
    PENTON, C
    PICKUP, JC
    [J]. DIABETES, 1986, 35 : A64 - A64
  • [10] Development of needle-type glucose sensor with high selectivity
    Yang, QL
    Atanasov, P
    Wilkins, E
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (03) : 249 - 256