CONCEPTION AND REALIZATION OF A PHOTOACOUSTIC DETECTOR FOR IN SITU SPECTROSCOPY.

被引:0
|
作者
Poulet, Patrick
Chambron, Jacques
机构
来源
Journal of photoacoustics | 1982年 / 1卷 / 03期
关键词
BIOLOGICAL MATERIALS - Skin - LIGHT - Absorption - SPECTROMETERS;
D O I
暂无
中图分类号
学科分类号
摘要
A photoacoustic spectrometer using an open-ended detector has been developed for doing in situ measurements. It makes use of a UV light guide and a differential microphone assembled in between two identical cells, one illuminated and the other not. The characteristics of this detector are expressed in terms of sensitivity to noise ratio. The equipment has enabled the authors to perform original applications of photoacoustic spectroscopy, especially in vivo measurements of skin optical absorption.
引用
收藏
页码:329 / 346
相关论文
共 50 条
  • [1] CORRELATION PHOTOACOUSTIC SPECTROSCOPY.
    Sugitani, Yoshinori
    Uejima, Akinori
    Kato, Kenji
    Journal of Photoacoustics, 1982, 1 (02): : 217 - 236
  • [2] PROPOSAL TO LOCALIZE AN INTRAOCULAR MELANOMA BY PHOTOACOUSTIC SPECTROSCOPY.
    Wolbarsht, M.L.
    Soviet journal of quantum electronics, 1981, 11 (12): : 1623 - 1624
  • [3] NUMERICAL MODEL OF SATURATION IN MEGAHERTZ PHOTOACOUSTIC SPECTROSCOPY.
    Burnham, Roger K.
    Grey, Gothard C.
    Eyring, Edward M.
    Journal of Photoacoustics, 1982, 1 (02): : 161 - 170
  • [4] NEW RESONANCE DETECTOR FOR MOSSBAUER SPECTROSCOPY.
    IRKAEV, S.M.
    MOROZOV, V.V.
    1982, V 27 (N 1): : 81 - 82
  • [5] Vibrational overtones of linear alkanes by laser photoacoustic spectroscopy.
    Daniel, MM
    Swofford, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 23 - ANYL
  • [6] WHOLE BLOOD - A SEDIMENTING SAMPLE STUDIED BY PHOTOACOUSTIC SPECTROSCOPY.
    Helander, Per
    Lundstrom, Ingemar
    Journal of Photoacoustics, 1982, 1 (02): : 203 - 215
  • [7] MECHANICAL DEGRADATION OF PVC FILMS MONITORED BY PHOTOACOUSTIC SPECTROSCOPY.
    Abu-Zeid, M.E.
    1600, (30):
  • [8] Monitoring of nitrogen and potassium deficiency in plants with photoacoustic spectroscopy.
    Rai, AK
    Singh, JP
    Reddy, KR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : B158 - B158
  • [9] WORKING CHARACTERISTICS OF A RESONANT DETECTOR FOR INTRACAVITY SPECTROSCOPY.
    Vul'fson, E.K.
    Dvorkin, V.I.
    Karyakin, A.V.
    Khomyak, A.S.
    1600, (39):
  • [10] ANALYSIS OF LIQUID SURFACE FILMS BY PULSED LASER PHOTOACOUSTIC SPECTROSCOPY.
    Sigrist, M.W.
    Chen, Z.H.
    Applied physics. B, Photophysics and laser chemistry, 1987, B43 (01): : 1 - 7