Voltammetric detection of nanomolar levels of hypoxanthine in the presence of copper (II) at glassy carbon electrode

被引:0
|
作者
机构
来源
Wuhan Univ J Nat Sci | / 1卷 / 99-102期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Nanomolar levels of the hypoxanthine in NaOH electrolyte containing copper (II) can be determined by anodic stripping voltammetry at a glassy carbon electrode. In the present article hypoxanthine-Cu+ is shown to be adsorbed on the electrode surface in the presence of an excess of copper (II). After accumulation period, hypoxanthine-Cu+ was stripped from the electrode surface and the anodic current coming near to the oxidation of Cu(I) to Cu(II) was measured. A linear calibration curve in the range of 5 nmol/L-1.5 nmol/L hypoxanthine, with a detection limit of 0.5 nmol/L hypoxanthine were obtained.
引用
收藏
相关论文
共 50 条
  • [31] A glassy carbon electrode modified with a copper tungstate and polyaniline nanocomposite for voltammetric determination of quercetin
    Ponnaiah, Sathish Kumar
    Periakaruppan, Prakash
    MICROCHIMICA ACTA, 2018, 185 (11)
  • [32] Square wave voltammetric determination of nitrate at a freshly copper plated glassy carbon electrode
    Solak, AO
    Çekirdek, P
    ANALYTICAL LETTERS, 2005, 38 (02) : 271 - 280
  • [33] Carbon nanotube-modified glassy carbon electrode for anodic stripping voltammetric detection of Uranyle
    Ahmad Nozad Golikand
    Mehdi Asgari
    Mohammad Ghannadi Maragheh
    Elaheh Lohrasbi
    Journal of Applied Electrochemistry, 2009, 39 : 65 - 70
  • [34] Carbon nanotube-modified glassy carbon electrode for anodic stripping voltammetric detection of Uranyle
    Golikand, Ahmad Nozad
    Asgari, Mehdi
    Maragheh, Mohammad Ghannadi
    Lohrasbi, Elaheh
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (01) : 65 - 70
  • [35] Differential pulse voltammetric determination of nanomolar concentrations of antiviral drug acyclovir at polymer film modified glassy carbon electrode
    Dorraji, Parisa S.
    Jalali, Fahimeh
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 61 : 858 - 864
  • [36] Nanomolar detection of hydrogen peroxide on glassy carbon electrode modified with electrodeposited cobalt oxide nanoparticles
    Salimi, Abdollah
    Hallaj, Rahman
    Soltanian, Saied
    Mamkhezri, Hussein
    ANALYTICA CHIMICA ACTA, 2007, 594 (01) : 24 - 31
  • [37] Voltammetric studies of spinach ferredoxin on a glassy carbon electrode modified with Cobalt(II) tetrasulfophthalocyanine
    Limson, J
    Nyokong, T
    ELECTROANALYSIS, 1998, 10 (14) : 988 - 993
  • [38] Anodic voltammetric behavior of inosine on a glassy carbon electrode
    Yang, YF
    Shi, L
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 219 - 222
  • [39] Adsorptive Voltammetric Determination of Nimesulide at Glassy Carbon Electrode
    El-Sayed, Gamal O.
    Yasin, Shalaby A.
    El Ries, Mohammed A.
    El-Badawy, Azza A.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2009, 28 (05): : 741 - 746
  • [40] Anodic voltammetric behavior of ethacridine at a glassy carbon electrode
    Yang, YF
    Zhang, YN
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (01) : 34 - 37