Electrochemical detection of glucose in sweat using a paper-based origami biosensor based on PEDOT:PSS/Ti3C2/MWCNT composite

被引:3
|
作者
Moradi, Sara [1 ]
Hosseini, Morteza [1 ,2 ]
Firoozbakhtian, Ali [1 ]
Tashnizi, Mohammad Barshan [3 ]
Ganjali, Mohammad Reza [4 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Life Sci Engn, Nanobiosensors Lab, Tehran 1439817435, Iran
[2] Univ Tehran Med Sci, Med Biomat Res Ctr, Tehran, Iran
[3] Univ Tehran, Fac New Sci & Technol, Dept Life Sci Engn, Tehran, Iran
[4] Univ Tehran, Coll Sci, Ctr Excellence Electrochem, Sch Chem, Tehran 1439817435, Iran
关键词
Origami; Paper-based-Biosensor; Glucose; Electrochemistry; Sweat; CARBON NANOTUBES; IMMOBILIZATION; ELECTRODE; DEVICE; ENZYME; SENSOR;
D O I
10.1016/j.jelechem.2024.118675
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Origami glucose biosensors utilize folding techniques to create compact, cost-effective devices for monitoring glucose levels and offer great potential in healthcare and diagnostics applications. The origami design of the biosensor allows for easy handling and transport, making it ideal for point-of-care testing in resource-limited areas, especially for individuals with diabetes to monitor glucose levels. This study introduced a novel paper-based origami glucose biosensor with graphite pencil electrodes which directly drawn onto the paper surface. A simple method used to draw two circular areas for effective immobilization of the mediator and glucose oxidase enzyme. A novel mediator composed of MWCNT and Ti3C2 dissolved in PEDOT:PSS ink was introduced to the mediator zone to enhance the paper surface's conductivity, thereby boosting the electron transfer rate from the enzyme region to the electrodes. The mediator ink was produced by using a straightforward one-step process, eliminating the necessity for specialized equipment and intricate synthesis techniques. Also, the mediator composite lowered the applied potential for glucose oxidation reaction according to the high surface area, unique electronic properties, and excellent catalytic activity of the composite. The lower potentials for glucose oxidation are required to avoid the electrochemical oxidation of interfering substances, to reach a high accuracy in the detection of the analyte. With a detection limit of 0.007 mM and linear range of 0.01 mM to 0.4 mM, it covers a wide range of glucose concentrations found in sweat.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A photoelectrochemical biosensor based on b-TiO2/CdS:Eu/Ti3C2 heterojunction for the ultrasensitive detection of miRNA-21
    Liu, Shen-Ting
    Chen, Jing-Shuai
    Liu, Xing-Pei
    Mao, Chang-Jie
    Jin, Bao-Kang
    TALANTA, 2023, 253
  • [32] Electrochemical Biosensor Based on HRP/Ti3C2/Nafion Film for Determination of Hydrogen Peroxide in Serum Samples of Patients with Acute Myocardial Infarction
    Xu, Wei
    Sakran, Marwan
    Fei, Jianwen
    Li, Xiaoyun
    Weng, Chenyuan
    Yang, Wei
    Zhu, Guomin
    Zhu, Wanying
    Zhou, Xuemin
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2021, 7 (06) : 2767 - 2773
  • [33] NiCo2O4/Ti2NbC2 (double MXene) nanohybrid-based non-enzymatic electrochemical biosensor for the detection of glucose in sweat
    Ashok Kumar Subramania
    Sivanandam Sugumaran
    Prakash Sethuramalingam
    Rajasekaran Ramesh
    Preethi Dhandapani
    Subramania Angaiah
    Bioprocess and Biosystems Engineering, 2023, 46 : 1755 - 1763
  • [34] NiCo2O4/Ti2NbC2 (double MXene) nanohybrid-based non-enzymatic electrochemical biosensor for the detection of glucose in sweat
    Subramania, Ashok Kumar
    Sugumaran, Sivanandam
    Sethuramalingam, Prakash
    Ramesh, Rajasekaran
    Dhandapani, Preethi
    Angaiah, Subramania
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2023, 46 (12) : 1755 - 1763
  • [35] Planar supercapacitor with high areal capacitance based on Ti3C2/Polypyrrole composite film
    Zhang, Chao
    Xu, Shuaikai
    Cai, Dong
    Cao, Junming
    Wang, Lili
    Han, Wei
    ELECTROCHIMICA ACTA, 2020, 330
  • [36] Smartphone-enabled 3D origami-fluidic paper-based electrochemical detection of myeloperoxidase activity for assessing wound infection
    Permpoka, Khageephun
    Purinai, Phongphisut
    Cheerasiri, Chaichalerm
    Rojpalakorn, Waranyoo
    Nilaratanakul, Voraphoj
    Laiwattanapaisal, Wanida
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 398
  • [37] High-performance flexible supercapacitor based on PEDOT:PSS wrapped delaminated Ti3C2Tx composite: Experimental and DFT validation
    Nandy, Gourab
    Shaw, Swati
    Ghosh, Subhradip
    Dasmahapatra, Ashok Kumar
    POLYMER, 2025, 323
  • [38] A "turn-on" nano-biosensor based on the Ti3C2(OH)2 MXene nanosheets and DNA-silver nanoclusters for miRNA detection
    Dehnoei, Mahsa
    Hosseini, Morteza
    Ahmadi-Sangachin, Elnaz
    Mousavizadegan, Maryam
    MICROCHEMICAL JOURNAL, 2024, 204
  • [39] Enhancing electrochemiluminescence for chloramphenicol detection based on the synergistic effect of doped Ti3C2 with ultrasound
    Zhang, Huixin
    Zhao, Rui
    Zhang, Feifei
    Xia, Jianfei
    Wang, Zonghua
    FOOD CHEMISTRY, 2024, 448
  • [40] Ti3C2 MXene-based nanozyme as coreaction accelerator for enhancing electrochemiluminescence of glucose biosensing
    Momeni, Fatemeh
    Khoshfetrat, Seyyed Mehdi
    Bagheri, Hasan
    Zarei, Kobra
    BIOSENSORS & BIOELECTRONICS, 2024, 250